Skip to main content

Table 2 *Significance of within treatment change, p < 0.001. IOP intraocular pressure, SLT selective laser trabeculoplasty

From: Repeatability of selective laser trabeculoplasty for open-angle glaucoma

  

SLT1 Mean (standard deviation)

SLT2 Mean (standard deviation)

Paired t-test p-value

IOP

Baseline (n = 137)

20.3 (5.2)

19.4 (5.0)

0.03

 

6–12 months (n = 130,119)

16.3 (4.3)

16.3 (4.8)

0.86

 

12–15 months (n = 100,99)

16.4 (3.9)

16.7 (4.7)

0.24

IOP

6–12 months

4.1 (4.8)*

2.9 (4.7)*

0.04

decrease

12–15 months

3.5 (4.7)*

2.2 (4.5)*

0.005

IOP %

6–12 months

17.7 (19.8)*

14.7 (24.2)*

0.32

reduction

12–15 months

14.5 (23.4)*

10.9 (22.2)*

0.11

  1. IOP and IOP reduction are in mmHg