Skip to main content

Table 3 Significance of within treatment change, **p < 0.001, *p < 0.01. IOP intraocular pressure, SLT selective laser trabeculoplasty

From: Repeatability of selective laser trabeculoplasty for open-angle glaucoma

  

SLT1 Mean (standard deviation)

SLT2 Mean (standard deviation)

Paired t-test p-value

IOP

Baseline (n = 62)

18.7 (3.8)

18.7 (3.5)

0.96

 

6–12 months (n = 61,52)

16.0 (4.3)

15.3 (3.8)

0.58

 

12–15 months (n = 49,44)

15.8 (3.3)

16.6 (4.5)

0.33

IOP

6–12 months

2.8 (3.7)**

3.4 (3.6)**

0.64

decrease

12–15 months

2.5 (3.0)**

1.9 (3.5)*

0.38

IOP %

6–12 months

17.7 (19.8)*

14.7 (24.2)*

0.32

reduction

12–15 months

12.7 (15.1)**

11.3 (19.7)*

0.74