Skip to main content

Table 2 Mean values and inter-eye symmetry of corneal biomechanical parameters in subjects

From: Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology

Parameters

Right eye

Left eye

Mean difference (95% CI)

P*

ICC

A1T, ms

7.424 ± 0.340

7.451 ± 0.365

−0.028 (-0.067 to 0.012)

0.167

0.906

A1L, mm

1.729 ± 0.066

1.726 ± 0.094

0.003 (-0.016 to 0.021)

0.784

0.415

A1V, m/s

0.139 ± 0.020

0.138 ± 0.026

0.001 (-0.004 to 0.005)

0.861

0.592

A1DA, mm

0.119 ± 0.009

0.116 ± 0.011

0.002 (0.001 to 0.004)

0.025

0.685

A2T, ms

21.586 ± 0.869

21.401 ± 1.216

0.184 (-0.097 to 0.466)

0.197

0.224

A2L,mm

1.688 ± 0.319

1.554 ± 0.383

0.133 (0.038 to 0.228)

0.006

0.199

A2V, m/s

−0.334 ± 0.102

−0.334 ± 0.078

0.0002 (-0.022 to 0.022)

0.985

0.451

A2DA, mm

0.367 ± 0.131

0.372 ± 0.141

−0.004 (-0.038 to 0.030)

0.800

0.396

HCT, ms

16.675 ± 0.502

16.735 ± 0.555

−0.060 (-0.197 to 0.077)

0.389

0.137

PD, mm

2.940 ± 1.083

2.686 ± 1.080

0.253 (-0.037 to 0.544)

0.086

0.027

RoC, mm

6.470 ± 1.295

6.438 ± 1.318

0.032 (-0.265 to 0.330)

0.831

0.449

MDA, mm

0.993 ± 0.102

0.982 ± 0.100

0.011 (-0.002 to 0.024)

0.088

0.872

  1. Data were presented as mean ± standard deviation
  2. 95% CI 95% confidential interval, *paired t test, ICC intraclass correlation coefficient
  3. A1T Time from start to the first flatterning of cornea, A1L Length of flattened cornea in the first applanation, A1V Inward velocity of the cornea in the first applanation, A1DA Cornea apex displacement in vertical direction at first applanation, A2T Time from start to second flattening of the cornea, A2L Length of flattened cornea in the second applanation, A2V Outward velocity of the cornea in the second applanation, A2DA Cornea apex displacement in vertical direction at second applanation, HCT Time from start to the highest concavity of cornea, PD Distance between the corneal peaks at maximal concavity, RoC Radius of curvature of the corneal at highest concavity, MDA Cornea apex displacement in vertical direction at highest concavity
  4. Bold indicates statistical significance (P < 0.05)