Table 3 Ocular Biometric Parameters Among Each Acute Angle-Closure Mechanism

From: Qualitative and quantitative evaluation of acute angle-closure mechanisms

Biometric Parameters

CR (N = 30)

LS (N = 19)

PB (N = 16)

PL (N = 6)

p-value*

ACD (mm)

1.7 ± 0.2

1.6 ± 0.3

1.9 ± 0.3

2.2 ± 0.2

<0.001

AL (mm)

22.3 ± 0.6

23.0 ± 1.4

22.6 ± 0.8

22.7 ± 0.5

0.07

LT (mm)

5.2 ± 0.3

5.0 ± 0.4

5.0 ± 0.3

5.0 ± 0.3

0.19

VL

14.9 ± 0.7

15.9 ± 1.6

15.1 ± 1.0

15.1 ± 0.4

< 0.05

LP

4.3 ± 0.3

4.1 ± 0.3

4.4 ± 0.3

4.7 ± 0.2

<0.001

RLP

1.9 ± 0.1

1.8 ± 0.2

1.9 ± 0.1

2.1 ± 0.1

<0.001

LAF

2.3 ± 0.1

2.2 ± 0.2

2.2 ± 0.2

2.2 ± 0.2

< 0.05

  1. ACD anterior chamber depth, LT lens thickness, VL vitreal length, AL axial length, LP lens position, RLP relative lens position, LAF lens axial length factor, CR crowded-angle, LS lens subluxation, PB pupillary block, PL plateau iris syndrome