Skip to main content

Table 1 Qualitative assessment of the distribution of RNFL thickness segmentation error comparing the IIH and control cohorts using median values and ranges

From: Segmentation error in spectral domain optical coherence tomography measures of the retinal nerve fibre layer thickness in idiopathic intracranial hypertension

Location

Overall IIH % error (n = 46)

Mild IIH % error (n = 23)

Moderate-severe IIH % error (n = 23)

Control % error (n = 14)

p overall

p moderate-severe

Using ImageJ

      

Total area of RNFL

5 (0–58)

2 (0–16)

10 (0–58)

1 (0–6)

0.009a

<0.001a

Using spectalis automated software

      

Average

 Overall

4 (0–58)

2 (0–16)

10 (0–58)

2 (0–6)

0.031a

0.002a

 Superior

8 (0–375)

6 (0–115)

11 (0–375)

3 (0–10)

0.007a

0.001a

 Nasal

2 (0–81)

2 (0–30)

1 (0–81)

1 (0–14)

NS

NS

 Inferior

4 (0–79)

3 (0–12)

6 (0–79)

2 (0–11)

0.031a

0.008a

Maximum

 Highest Single Point

5 (0–62)

5 (0–43)

7 (0–62)

4 (0–14)

NS

NS

 Superior

7 (0–60)

5 (0–42)

12 (0–60)

3 (0–26)

0.044a

0.017a

 Nasal

6 (0–70)

5 (0–51)

8 (0–70)

7 (0–133)

NS

NS

 Inferior

5 (0–96)

3 (0–114)

7 (0–96)

3 (0–17)

NS

0.049a

 Temporal

3 (0–43)

3 (0–21)

3 (0–43)

1 (0–28)

NS

NS

  1. NB values are compared with the control group. There were no significant differences in mild disc swelling for any of the above parameters. NS not significant; aindicates statistical significance