Skip to main content

Table 2 Binocular visual acuities in patients implanted with ZKB00 and ZLB00 multifocal IOLs at preoperative, 1 month and 3 months after surgery

From: Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans

Measurements

Preoperative

1 month

p valuea

3 months

p valueb

CDVA at 5 m

0.03 ± 0.12

− 0.11 ± 0.08

0.001

−0.12 ± 0.08

0.001

UDVA at 5 m

0.36 ± 0.27

−0.10 ± 0.10

< 0.001

−0.08 ± 0.10

< 0.001

UIVA at 80 cm

0.50 ± 0.27

0.21 ± 0.23

0.013

0.12 ± 0.14

< 0.001

UIVA at 60 cm

0.51 ± 0.18

0.10 ± 0.14

0.003

0.09 ± 0.09

0.003

UNVA at 50 cm

0.43 ± 0.19

0.10 ± 0.10

< 0.001

0.07 ± 0.11

< 0.001

UNVA at 43 cm

0.45 ± 0.17

0.16 ± 0.15

< 0.001

0.14 ± 0.09

< 0.001

UNVA at 33 cm

0.31 ± 0.30

0.27 ± 0.23

0.491

0.25 ± 0.11

0.348

  1. CDVA Corrected distance visual acuity, UDVA Uncorrected distance visual acuity, UIVA Uncorrected intermediate visual acuity, UNVA Uncorrected near visual acuity