Skip to main content

Table 3 Arithmetic error and absolute error of prediction using different K readings

From: Keratometric measurements and IOL calculations in pseudophakic post-DSAEK patients

Method

n

Arithmetic Error (D)

Absolute Error (D)

Mean(D) ± SD

Minimum - Maximum

Range

Mean(D) ± SD

Minimum - Maximum

Range

KMaster

20

0.44 ± 1.02

−1.70 to 2.32

4.02

0.89 ± 0.63

0.01 to 2.32

2.31

SimK

20

0.32 ± 1.03

−1.90 to2.32

4.22

0.82 ± 0.68

0.05 to 2.32

2.27

EKR

20

−0.05 ± 1.02

−2.40 to 1.91

4.31

0.74 ± 0.68

0.03 to 2.40

2.37

TNP

20

−1.35 ± 1.06

−3.90 to 0.76

4.66

1.42 ± 0.95

0.05 to 3.90

3.85

  1. KMaster conventional K via IOLMaster, SimK simulated keratometer reading, EKR equivalent K reading, TNP true net power