Skip to main content

Table 2 Time courses of the visual and refractive outcomes between the SMILE (− 6.25 to − 10 D) and EVO-ICL (− 6.25 to − 10 D) groups

From: Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia

 

Preoperative

Postoperative period

P-value

1 week

1 month

3 month

 

LogMAR UDVA

    

SMILE (− 6.25 to − 10 D)

1.33 ± 0.23

−0.01 ± 0.06

− 0.04 ± 0.06

− 0.04 ± 0.07

P0 = 0.000*

EVO-ICL (− 6.25 to − 10 D)

1.36 ± 0.27

0.00 ± 0.10

−0.04 ± 0.06

− 0.06 ± 0.05

P0 = 0.000*

P-value

P1 = 0.650

P1 = 0.448

P1 = 0.720

P1 = 0.207

 
 

LogMAR BCVA

    

SMILE (−6.25 to −10 D)

−0.04 ± 0.04

− 0.02 ± 0.06

−0.05 ± 0.05

− 0.05 ± 0.06

P0 = 0.318

EVO-ICL (− 6.25 to − 10 D)

−0.04 ± 0.05

− 0.04 ± 0.06

−0.05 ± 0.05

− 0.06 ± 0.04

P0 = 0.003*

P-value

P1 = 0.763

P1 = 0.324

P1 = 0.698

P1 = 0.345

 
 

spherical equivalent(D)

    

SMILE (−6.25 to −10 D)

− 6.00 ± 1.68

0.04 ± 0.19

0.00 ± 0.21

−0.06 ± 0.31

P0 = 0.000*

EVO-ICL (−6.25 to −10 D)

− 6.15 ± 1.72

0.03 ± 0.20

−0.01 ± 0.20

0.01 ± 0.20

P0 = 0.000*

P-value

P1 = 0.189

P1 = 0.773

P1 = 0.892

P1 = 0.285

 
  1. P0 = P-value of the difference between the preoperative and three month values; P1 = P-value of the difference between the SMILE (−6.25 to −10 D) and EVO-ICL implantation (− 6.25 to − 10 D) groups; *P < 0.05 = significant difference
  2. LogMAR logarithm of the minimal angle of resolution, UDVA uncorrected distance visual acuity BCVA best-corrected distance visual acuity, D diopter