Skip to main content

Table 2 Comparison of angle structures measurements between SS-OCT and SD-OCT

From: Comparison of spectral domain and swept source optical coherence tomography for angle assessment of Chinese elderly subjects

  

TOMEY

OPTOVUE

P value

Correlation

P valuec

LTM

(N)

702.49 ± 108.32

657.08 ± 112.15

0.002

0.510

0.000

(μm)

(T)

669.84 ± 100.21

648.67 ± 101.82

0.137

0.418

0.009

AOD500

(N)

283.64 ± 128.56

314.98 ± 148.52

0.000a

0.897b

0.000

(μm)

(T)

333.99 ± 150.12

370.36 ± 186.85

0.000a

0.811b

0.000

AOD750

(N)

391.33 ± 176.86

424.06 ± 196.32

0.000a

0.927b

0.000

(μm)

(T)

462.30 ± 216.61

491.93 ± 255.04

0.009a

0.811b

0.000

LSC

(N)

225.91 ± 41.44

215.70 ± 50.82

0.074

0.704

0.003

(μm)

(T)

243.85 ± 43.34

215.83 ± 37.99

0.007

0.093

0.597

  1. LTM Length of trabecular meshwork, AOD500 Angle opening distance 500 μm, AOD750 Angle opening distance 750 μm, LSC Length of Schlemm’s canal
  2. a Wilcoxon rank-sum test
  3. b Spearman’s rank correlation coefficient
  4. c This P value is for correlation