Skip to main content

Table 4 Binocular visual acuity in multifocal IOL group and monofocal IOL group at 3 month postoperatively

From: Clinical outcomes after mix-and-match implantation of diffractive multifocal intraocular lenses with + 2.75 and + 4.00 diopter add powers

 

Preoperative

P value+

3-month postoperative

P value*

P value+

LogMAR UDVA

(multifocal IOL group)

0.31 ± 0.31

(range: 0.10–0.60)

0.824

0.01 ± 0.04

(range: 0–0.10)

0.011

0.702

LogMAR UDVA

(monofocal IOL group)

0.34 ± 0.28

(range: 0.10–0.60)

0.03 ± 0.04

(range: 0–0.20)

0.009

LogMAR UIVA

(multifocal IOL group)

0.56 ± 0.23

(range: 0.30–0.80)

0.659

0.16 ± 0.05

(range: 0–0.20)

0.011

0.006

LogMAR UIVA

(monofocal IOL group)

0.49 ± 0.28

(range: 0.20–0.80)

0.35 ± 0.22

(range: 0.20–0.70)

0.120

LogMAR UNVA

(multifocal IOL group)

0.48 ± 0.25

(range: 0.20–0.80)

0.701

0.11 ± 0.07

(range: 0–0.30)

0.017

0.002

LogMAR UNVA

(monofocal IOL group)

0.43 ± 0.26

(range: 0.20–0.80)

0.37 ± 0.21

(range: 0.20–0.70)

0.305

LogMAR CDVA

(multifocal IOL group)

0.09 ± 0.13

(range: 0–0.30)

0.871

0.01 ± 0.03

(range: 0–0.10)

0.084

0.888

LogMAR CDVA

(monofocal IOL group)

0.10 ± 0.10

(range: 0–0.20)

0.01 ± 0.03

(range: 0–0.10)

0.086

  1. Results reported as means ± standard deviations
  2. UDVA Uncorrected distance visual acuity, UIVA Uncorrected intermediate visual acuity, UNVA Uncorrected near visual acuity, CDVA Corrected distance visual acuity, IOL Intraocular lenses
  3. *Compared with preoperative values
  4. +Compared between multifocal IOL group and monofocal IOL group