Skip to main content

Table 4 Univariable and multivariable logistic regression analysis showing the odds of glaucoma for average SVOP sensitivity, amplitude bias, direction bias, average latency, latency standard deviation and age

From: Speed and accuracy of saccades in patients with glaucoma evaluated using an eye tracking perimeter

 

Univariable Analysis

Multivariable Analysis

 

Coefficient

95% CI

P-value

Coefficient

95% CI

P-value

SVOP sensitivity (dB)

2.076

1.534 to 2.810

< 0.001

2.102

1.492 to 2.961

< 0.001

Amplitude Bias (%)

1.013

0.986 to 1.040

0.346

NA

NA

NA

Direction Bias (degrees)

1.021

0.9745 to 1.070

0.378

NA

NA

NA

Average Latency (ms)

1.011

1.002 to 1.020

0.012

1.004

0.989 to 1.018

0.796

Latency standard deviation (ms)

1.013

0.998 to 1.028

0.088

1.004

0.979 to 1.030

0.762

Age (years)

1.138

1.069 to 1.212

< 0.001

0.990

0.893 to 1.090

0.796