Table 8 Comparison of AUROCs between RGCcount and OCT parameters, in all myopes groups

From: Diagnostic ability of OCT parameters and retinal ganglion cells count in identification of glaucoma in myopic preperimetric eyes

 

Emmetropes

Myopes with AL < 25 mm

Myopes with AL > 25 mm

All myopes

 

AUC

p *

Difference between areas (SE)

p

AUC

p *

Difference between areas (SE)

p

AUC

p *

Difference between areas (SE)

p

AUC

p*

Difference between areas (SE)

p

RGC count (n)

0.873

< .001

/

/

0.929

< .001

/

/

0.905

< .001

/

/

0.895

< .001

/

 

MD (dB)

0.807

< .001

0.0665 (0.0476)

0.16

0.528

0.72

0.402 (0.0792)

<.001

0.733

0.0004

0.172 (0.07)

0.008

0.636

0.008

0.25 (0.05)

<.001

RNFL avg. (μm)

0.877

< .001

0.00416 (0.0463)

0.93

0.951

< .001

0.0214 (0.354)

0.55

0.883

< .001

0.0216 (0.0497)

0.66

0.899

< .001

0.00322 (0.0285)

0.91

RNFL sup (μm)

0.798

< .001

0.0716 (0.0558)

0.2

0.912

< .001

0.0171 (0.0414)

0.7

0.859

< .001

0.0455 (0.0532)

0.39

0.87

< .001

0.0258 (0.0334)

0.44

RNFL inf (μm)

0.88

< .001

0.0107 (0.0496)

0.83

0.949

< .001

0.0192 (0.309)

0.53

0.872

< .001

0.0325 (0.0525)

0.54

0.885

< .001

0.0102 (0.032)

0.75

GCC avg. (μm)

0.748

< .001

0.125 (0.0704)

0.08

0.995

< .001

0.0652 (0.0375)

0.08

0.974

< .001

0.693 (0.0476)

0.42

0.981

< .001

0.0862 (0.0337)

0.01

GCC sup (μm)

0.673

< .001

0.197 (0.0821)

0.02

0.951

< .001

0.0214 (0.0451)

0.64

0.963

< .001

0.0584 (0.0489)

0.23

0.953

< .001

0.058 (0.0373)

0.12

GCC inf (μm)

0.801

< .001

0.0748 (0.0618)

0.23

0.998

< .001

0.0684 (0.0382)

0.73

0.976

< .001

0.07 (0.05)

0.13

0.987

< .001

0.0918 (0.0329)

0.005

FLV %

0.897

< .001

0.0278 (0.0731)

0.7

0.949

< .001

0.0192 (0.0502)

0.7

0.9

< .001

0.00433 (0.0555)

0.94

0.917

< .001

0.0215 (0.0386)

0.58

GLV %

0.818

< .001

0.0603 (0.0705)

0.39

0.996

< .001

0.0662 (0.0369)

0.07

0.998

< .001

0.09 (0.04)

0.03

0.987

< .001

0.0913 (0.0312)

0.004

  1. *Area under receiver operating characteristic curve values and p-values describing glaucomatous diagnostic capabilities of RGCcount and OCT parameters in emmetropic eyes, all myopic eyes, myopes with AL < 25 mm eyes and myopes with AL > 25 mm eyes
  2. P-values significant for p < 0.05