Skip to main content

Table 5 Factors associated with unstable prediction error in combined group at 12 months postoperatively

From: Long-term outcomes of prediction error after combined phacoemulsification and trabeculectomy in glaucoma patients

Variables Univariable analysis Multivariable analysis *
OR 95% CI P value a OR 95% CI P value a
Age, per 1 year older 1.060 1.005–1.118 0.031 1.069 1.007–1.135 0.030
Male gender 1.000 0.360–2.777 1.000    
ACG 1.000 0.360–2.777 1.000    
Baseline BCVA, per 1 increase 1.229 0.651–2.321 0.524    
Baseline IOP, per 1 mmHg increase 0.953 0.903–1.006 0.084 0.963 0.905–1.024 0.229
AL, per 1 mm increase 1.090 0.667–1.782 0.730    
ACD, per 1 mm increase 1.449 0.511–4.103 0.485    
LV, per 1 mm increase 6.838 1.043–44.809 0.045 5.687 1.195–27.064 0.029
AV, per 1 mm increase 4.873 1.210–19.625 0.047 6.231 0.755–51.425 0.089
  1. OR odds ratio, CI confidence interval, ACG angle closure glaucoma, BCVA best-corrected visual acuity, IOP intraocular pressure, AL axial length, ACD anterior chamber depth, LV lens vault, AV anterior vault
  2. aLogistic regression analysis
  3. * Only variables with a P value of less than .10 in the univariable analysis were included in the multivariable model
\