Skip to main content

Table 3 Spearman’s correlation analysis and stepwise multiple regression analysis between the 1-month ICL vault and other variables

From: Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation

 

Spearman’s correlation

Multivariable analysis

(constant=-1369.05; R = 0.813; R2 = 0.660; adjusted R2 = 0.643)

Variables

r

P value

Partial regression coefficient (B)

Standardized partial regression coefficient (β)

P value

Age

-0.313

0.004

   

SE

0.019

0.861

   

Keratometric value

 Flat K

0.147

0.185

   

 Steep K

0.070

0.531

   

 Mean K

0.133

0.232

   

STS

 Vertical

-0.140

0.206

-137.330

-0.257

0.017

 Horizontal

0.060

0.592

-287.408

-0.517

< 0.001

IOP

-0.157

0.156

   

AL

0.001

0.990

   

ACD

0.261

0.017

   

WTW diameter

 Pentacam

0.288

0.008

   

 OPD-Scan III

0.242

0.028

   

 IOLMaster 700

0.255

0.020

   

Pupil size

 Bright

0.103

0.353

   

 Dark

0.140

0.207

   

 Dark-bright

0.129

0.246

   

ICL size

0.450

< 0.001

657.121

0.942

< 0.001

Crystalline lens thickness

-0.603

< 0.001

-432.497

-0.376

< 0.001

Central corneal thickness

-0.201

0.068

   
  1. STS sulcus-to-sulcus, WTW white-to-white, IOP intraocular pressure, ACD anterior chamber depth