Skip to main content

Table 2 Pupil dynamics and transient eye closure (TEC) using a near infrared vision monitoring system

From: Investigation of transient eye closure evoked with bright light in the patients with intermittent exotropia

Dynamics of pupil

Transient eye closure (−)

(mean ± SD)

Transient eye closure (+)

(mean ± SD)

P-value

Initial diameter (mm)

R

5.26 (±0.81)

5.71 (±0.27)

0.14

L

5.35 (±0.71)

5.69 (±0.22)

0.18

Amplitude of contraction (mm)

R

1.96 (±0.30)

2.21 (±0.30)

0.90

L

2.09 (±0.24)

2.18 (±0.27)

0.41

Latency of contraction (ms)

R

193.6 (±35.47)

198.3 (±74.15)

0.85

L

191.0 (±35.81)

202.3 (±75.45)

0.66

Duration of contraction (ms)

R

642.9 (±65.47)

651.2 (±108.44)

0.83

L

681.6 (±84.35)

670.3 (±87.74)

0.76

Velocity of contraction (mm/s)

R

6.98 (±1.96)

7.33 (±1.32)

0.63

L

7.20 (±1.05)

7.77 (±2.51)

0.50

Latency of dilation (ms)

R

836.5 (±78.86)

849.5 (±54.80)

0.66

L

881.6 (±72.72)

862.8 (±65.91)

0.53

Duration of dilation (ms)

R

1630.9 (±72.72)

1624.5 (±58.06)

0.82

L

1586.2 (±79.82)

1624.7 (±44.37)

0.20

Velocity of dilation (mm/s)

R

2.63 (±1.10)

3.00 (±0.80)

0.38

L

2.52 (±0.59)

3.00 (±0.70)

0.13

  1. R Right eye, L Left eye, SD Standard deviation