Skip to main content

Table 1 Demographic data of the subjects for analysis

From: Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics

IOL

EDOF

Monofocal

P value

 

27 eyes

27 eyes

 

Age, year

69.0 (4.2)

[62 – 79]

70.9 (4.5)

[62 – 78]

0.10*

Axial length, mm

23.8 (1.5)

[21.9 – 28.2]

23.9 (0.9)

[22.7 – 26.1]

0.68*

Mean keratometry, D

44.5 (1.5)

[41.0 – 47.8]

43.8 (1.4)

[40.9 – 46.3]

0.08*

CDVA, logMAR

−0.16 (0.05)

[− 0.18 – 0.00]

−0.16 (0.04)

[− 0.18 – − 0.08]

0.95#

MRSE, D

−0.37 (0.37)

[− 1.25 – 0.25]

−0.10 (0.36)

[− 1.00 – 0.63]

0.010*

  1. Mean (standard deviation) [range]
  2. *: unpaired t-test, #: Mann-Whitney test, IOL intraocular lens, D diopter, CDVA corrected distance visual acuity, MRSE manifest refraction spherical equivalent, EDOF extended depth of focus