Skip to main content

Table 3 Endothelial cell density of confocal and specular microscopy

From: Corneal confocal microscopic characteristics of acute angle-closure crisis

  AACC eye (n = 37a) Fellow eye (n = 41) Healthy control (n = 40) P#
Vision (LogMAR) 1.4 ± 1.1 0.3 ± 0.2 0.8 ± 0.4 < 0.001
IOP (mmHg) 27.1 ± 15.4 12.4 ± 3.1 13.1 ± 2.9 < 0.001
Endothelial cell density
 CM 1654 ± 999 2601 ± 529 2593 ± 256 < 0.001
 SM 1982 ± 812b 2544 ± 473 2554 ± 224 < 0.001
P* 0.674 0.247 0.941  
  1. AACC Acute angle-closure crisis, IOP Intraocular pressure, CM Confocal microscopy, SM Specular microscopy
  2. #Comparison among AACC eye, fellow eye and healthy controls
  3. *Comparison between confocal microscopy and specular microscopy
  4. aThe data of 37 eyes and 24 eyes were analyzed by confocal microscopy and specular microscopy, respectively
  5. bComparison between AACC eye and fellow eye