From: Selective laser trabeculoplasty for early glaucoma: analysis of success predictors and adjusted laser outcomes based on the untreated fellow eye
Variables
Adjusted
Non-adjusted
Delta IOP (±SD), mmHg
5.1 ± 3.8 (range -2 to 21)
5.8 ± 3.8 (range 0 to 20)
Delta IOP (±SD), %
23.1 ± 14.3 (range -14.3 to 75)
26 ± 12.6 (range 0 to 51.3)
Success Rate, %
64%
76%