Skip to main content

Table 1 GCIPL thickness (Mean ± SD, μm) measured by two operators using macular cube 512 × 128 scanning protocol

From: Reproducibility of macular ganglion cell–inner plexiform layer thickness in normal eyes determined by two different OCT scanning protocols

Parameter

Operator

1st Measurement

2nd Measurement

3rd Measurement

P a

P b

Average

A

84.33 ± 5.76

84.27 ± 5.54

84.23 ± 5.63

0.991

0.846

B

84.38 ± 5.58

84.42 ± 5.59

84.39 ± 5.64

0.999

Minimum

A

81.44 ± 5.61

81.65 ± 5.30

81.23 ± 5.76

0.859

0.850

B

81.79 ± 5.72

81.71 ± 5.69

81.16 ± 5.97

0.689

Superotemporal

A

82.88 ± 5.29

82.82 ± 5.20

82.80 ± 5.42

0.993

0.938

B

82.74 ± 5.41

82.73 ± 5.36

82.71 ± 5.35

0.999

Superior

A

85.48 ± 6.15

85.33 ± 5.90

85.38 ± 5.99

0.983

0.935

B

85.31 ± 5.88

85.31 ± 5.89

85.41 ± 5.93

0.992

Superonasal

A

87.06 ± 6.57

86.86 ± 6.40

86.77 ± 6.56

0.943

0.966

B

86.76 ± 6.37

86.88 ± 6.30

86.82 ± 6.43

0.990

Inferonasal

A

84.94 ± 6.46

84.96 ± 6.24

84.91 ± 6.06

0.998

0.847

B

85.29 ± 6.13

85.17 ± 6.11

85.34 ± 6.39

0.978

Inferior

A

82.42 ± 6.25

82.44 ± 6.03

82.30 ± 6.07

0.982

0.792

B

82.72 ± 6.20

82.73 ± 6.29

82.79 ± 6.38

0.996

Inferotemporal

A

83.27 ± 5.81

83.38 ± 5.67

83.34 ± 5.86

0.990

0.916

B

83.46 ± 5.68

83.56 ± 5.82

83.53 ± 5.91

0.991

  1. acomparison between the three repeated measurements of the GCIPL thickness measured by each operator