Skip to main content

Table 3 Changes in macular thickness in subgroups at baseline and follow-ups

From: Subthreshold micropulse laser therapy for early postoperative macular thickening following surgical removal of epiretinal membrane

 

Group

Baseline

1-month follow-up

3-month follow-up

P value

(Baseline vs. 1-month)

P value

(Baseline vs. 3-month)

CST

SMPL

457.0 ± 70.1 (342 ~ 569)

438.8 ± 92.9 (273 ~ 635)

379.2 ± 75.3 (194 ~ 482)

0.711 a

0.004 a

Observation

430.5 ± 65.8 (266 ~ 540)

404.0 ± 63.5 (309 ~ 543)

385.5 ± 65.3 (274 ~ 555)

0.339 a

0.049 a

AMT

SMPL

340.9 ± 39.0 (281 ~ 425)

324.4 ± 36.6 (265 ~ 398)

304.0 ± 33.8 (253 ~ 374)

0.269 a

0.002 a

Observation

330.2 ± 34.0 (280 ~ 405)

310.5 ± 29.6 (276 ~ 390)

296.2 ± 30.0 (267 ~ 386)

0.082 a

0.001 a

  1. Data were presented as mean ± SD (range)
  2. CST Central subfield thickness, AMT Average macular thickness, SMPL Subthreshold micropulse laser, SD Standard deviation
  3. Pa, One-Way ANOVA test