Table 7 Performance between groups on the Intraocular Lens implantation (IOL) module

From: Virtual phacoemulsification surgical simulation using visual guidance and performance parameters as a feasible proficiency assessment tool

Performance Parameter Mean (SD) Z statistic ρ – value
Group A (n = 6) Group B (n = 10)
IOL1 8.3 (1.12) 9.4 (0.50) −3.628 0.011*
IOL2 4.4 (2.87) 1.8 (0.81) −3.736 0.048*
IOL3 1.0 (0.57) 0.4 (0.12) −4.266 0.041*
IOL4 167.8 (42.00) 103.7 (14.14) −4.836 0.029*
  1. Note: *Statistically Significant using Mann–Whitney test (ρ < 0.05)
\