Table 4 Comparison of optical quality changes between Group H and S under dark conditions

From: Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions

Parameter

Time

Group H

Group S

P-value

ΔOSI

1 week

−0.325 ± 0.121

− 1.606 ± 0.198

0.001

1 month

−0.379 ± 0.116

−1.746 ± 0.212

0.001

3 months

−0.429 ± 0.125

− 1.727 ± 0.217

0.002

ΔMTF cutoff frequency

1 week

1.623 ± 1.587

7.443 ± 2.308

0.012

1 month

1.347 ± 1.593

8.399 ± 2.476

0.004

3 months

2.994 ± 1.533

10.503 ± 2.274

0.001

ΔStrehl ratio

1 week

0.006 ± 0.008

0.036 ± 0.012

0.011

1 month

0.006 ± 0.009

0.038 ± 0.013

0.011

3 months

0.016 ± 0.010

0.048 ± 0.013

0.016

ΔOV100%

1 week

0.058 ± 0.053

0.237 ± 0.077

0.020

1 month

0.042 ± 0.053

0.275 ± 0.082

0.005

3 months

0.099 ± 0.051

0.335 ± 0.076

0.002

ΔOV20%

1 week

0.025 ± 0.043

0.169 ± 0.061

0.018

1 month

0.052 ± 0.042

0.203 ± 0.063

0.016

3 months

0.089 ± 0.043

0.254 ± 0.060

0.006

ΔOV9%

1 week

0.015 ± 0.026

0.106 ± 0.037

0.013

1 month

0.019 ± 0.027

0.110 ± 0.038

0.017

3 months

0.058 ± 0.034

0.137 ± 0.043

0.048

  1. ICL implantable collamer lens, OSI objective scattering index, MTF modulation transfer function, OV optical quality analysis system value