Table 2 Mean arithmetic values and power vectors for total corneal refractive power within 2.0–5.0 mm zones

From: Analysis of total corneal astigmatism with a rotating Scheimpflug camera in keratoconus

 

2.0 mm

zone

3.0 mm

zone

4.0 mm

zone

5.0 mm

zone

* p value

Centered on pupil

Mean keratometry (diopter)

48.28 ± 5.19

47.96 ± 4.53

47.62 ± 3.83

47.20 ± 3.15

0.005

Mean arithmetic

astigmatism (diopter)

3.62 ± 2.50

4.32 ± 2.11

4.52 ± 1.99

4.41 ± 1.97

< 0.001

KP(0) (diopter)

− 1.70 ± 2.72

− 2.42 ± 3.09

− 2.83 ± 3.23

− 2.99 ± 3.13

< 0.001

KP(45) (diopter)

1.44 ± 2.66

1.38 ± 2.45

1.21 ± 2.16

1.05 ± 1.91

0.17

Centered on apex

Mean keratometry (diopter)

49.83 ± 5.92

49.29 ± 5.16

48.68 ± 4.31

48.03 ± 3.99

< 0.001

Mean arithmetic

astigmatism (diopter)

5.35 ± 3.16

5.02 ± 2.66

4.61 ± 2.16

4.15 ± 1.81

< 0.001

KP(0) (diopter)

−2.64 ± 4.15

−2.70 ± 3.75

−2.68 ± 3.30

−2.59 ± 2.87

0.32

KP(45) (diopter)

1.72 ± 3.43

1.53 ± 2.97

1.35 ± 2.49

1.12 ± 2.12

0.001

** p value for mean keratometry

< 0.001

< 0.001

< 0.001

< 0.001

 

** p value for mean arithmetic astigmatism

< 0.001

< 0.001

0.62

0.07

** p value for KP(0)

0.025

0.60

0.19

0.002

** p value for KP(45)

0.011

0.076

0.068

0.36

  1. *Friedman test was used in comparison of keratometric values according to measurement zone
  2. ** Wilcoxon signed ranked test was used in comparison of keratometric values centered on pupil versus apex