Skip to main content

Table 1 Nomogram of the full-thickness astigmatic keratotomy

From: Two-year outcomes after full-thickness astigmatic keratotomy combined with small-incision lenticule extraction for high astigmatism

Distance from corneal marking (mm)

Incision width (mm)

Corrected astigmatism (D)

1.5

2.8

0.75

1.5

4.1

1.25

1.5

5.7

2.5

1.0

2.8

1

1.0

4.1

1.75

1.0

5.7

3

0.5

4.1

2

0.5

5.7

3.5

0

5.7

4.5