Skip to main content

Table 3 Correlation of AL elongation with the area and volume of the corneal refractive change region in the SE > -3.0 D subgroup

From: Relationship between myopia control and amount of corneal refractive change after orthokeratology lens treatment

Variable

β

Standard error

Standard β

95% CI

P value

Intercept

-4.355

2.323

 

(-9.088, 0.378)

0.070

CRC-region area

-0.017

0.007

-0.390

(-0.030, -0.003)

0.016

CRC-region volume

-0.001

0.001

-0.310

(-0.002, 0.0002)

0.101

Gender

     

Male

-0.012

0.044

-0.040

(-0.101, 0.077)

0.779

Female (ref.)

     

Age

-0.034

0.011

-0.400

(-0.056, -0.011)

0.005

Baseline AL

0.096

0.045

0.553

(0.004, 0.188)

0.041

Corneal thickness

0.001

0.001

0.157

(-0.0004, 0.002)

0.226

Flat K

0.055

0.027

0.439

(-0.001, 0.111)

0.055

Flat E

0.183

0.166

0.139

(-0.155, 0.521)

0.279

Pupil size

0.002

0.014

0.017

(-0.027, 0.032)

0.881

  1. The adjusted R-squared was 0.496
  2. AL Axial length, SE Spherical equivalent, CI Confidence interval