Skip to main content

Table 2 Intraoperative parameters of macula-on giant retinal tear detachments managed with silicone oil versus gas endotamponade

From: Management of macula-on giant retinal tear detachments– outcome of pars-plana-vitrectomy with silicone oil versus gas tamponade

intraoperative parameters

silicone oil group

( n = 32)

gas group

(n = 19)

p-value

cut-suture-time (minutes)

73 (SD 23.8)

50 (SD 8.5)

< 0.001 *

phakovitrectomy

18 (56%)

11 (58%)

0.909

laser spots

840 (SD 325.6)

828 (SD 250.8)

0.890

360° laser retinopexy

21 (66%)

18 (95%)

0.018 #

cryopexy

29 (91%)

17 (89%)

0.894

  1. * significant using Bonferroni correction, # not significant using Bonferroni correction