Pseudophakic ametropia management with toric implantable collamer lens with a central hole (case report)
BMC Ophthalmology volume 17, Article number: 17 (2017)
Abstract
Background
To report the clinical outcomes of correcting pseudophakic ametropia using toric implantable collamer lens with a 360 um central hole (TICL V4c).
Case presentation
The right eye of a 22-year-old male patient developed high myopia after unilateral phacoemulsification and intraocular lens (IOL) implantation following traumatic cataract 16 years ago. The manifest refraction was -11.50 DS/-2.50 DC × 175 with an uncorrected distance visual acuity (UDVA) of 20/2000 and a corrected distance visual acuity (CDVA) of 20/20. The manifest refraction of left eye was -6.25 DS/-3.75 DC × 180 with UDVA 20/200 and CDVA 20/20. Both eyes were implanted posterior chamber TICL V4c lens. Postoperatively, the refractive errors were +1.00 DS/-0.50 DC × 50 with UDVA 20/16 and CDVA 20/16 in the right eye and +0.75 DS/-0.75 DC × 45 with UDVA 20/16 and CDVA 20/13 in the left eye, respectively. No complications were observed.
Conclusions
TICL V4c is safe, effective and predictable in managing pseudophakic ametropia.
Background
Pseudophakic ametropia can be corrected by spectacles, contact lenses, intraocular lens (IOL) supplementation or exchange [1, 2], and corneal refractive surgeries [3, 4]. Spectacles offer an inconvenient approach and contact lenses have potential risks of dry eye and infectious keratitis. IOL exchange is a difficult option with potential complications of capsule tear, vitreous loss, and retinal detachment, especially if the lens is adherent to the capsular bag [2]. Corneal refractive surgeries can be used to correct lower amount of refractive errors when corneal thickness is in the safe range, but corneal scarring or haze, flap complications and regression may be the complications [3, 4]. In cases of higher refractive errors, the new posterior chamber implantable collamer lens (ICL V4c) provides an alternative approach, as corneal thickness may not meet the requirements of large refractive corrections. The new 360 μm central hole design of ICL V4c allows for the natural flow of aqueous humor without the need for a peripheral iridotomy [5]. This study investigates the clinical outcomes of correcting high myopia of a young adult in the management of pseudophakic ametropia using TICL V4c.
Case presentation
The right eye of a 22-year-old male patient developed high myopia after unilateral phacoemulsification and intraocular lens (IOL) implantation following traumatic cataract 16 years ago and the patient had an urgent desire to get rid of the spectacles. A comprehensive ophthalmic examination was performed preoperatively in Eye and ENT Hospital of Fudan University. An IOL in the capsular bag with posterior capsular opacification was observed in the right eye, as well as corneal scar and oval pupil with pupillary margin adhesion (Fig. 1). No other disease was found in the remaining examination. Ultrasound biomicroscopy (UBM, 50 MHZ, AVISO V:4.0.2, Quantel Medical, France) shows the IOL in the capsular bag of the right eye, adhesion between the temporal and subtemporal pupillary margin and the anterior capsule, the crystal lens of the left eye and all suspensory ligament of both eyes in position (Fig. 2).
Preoperative data was summarized in Table 1. The manifest refraction was -11.50 DS/-2.50 DC* 175 in the right eye and -6.25 DS/-3.75 DC* 180 in left, with the CDVA being 20/20 in both eyes. The patient was not a suitable candidate for corneal laser refractive surgeries because of the relatively thin cornea (479, 478 microns, respectively). Then ICL was implanted in the in the sulcus of both eyes, leaving the previously implanted IOL in the capsular bag of the right eye. ICL power calculations were performed by the manufacturer (STAAR Surgical) using a modified vertex formula. The size (length) of the implanted ICL was determined based on the patient’s anterior chamber depth (ACD) and white-to-white (WTW), sulcus to sulcus (STS). The ICL power of the left eye was -10.5/+3.5/090, with the length being 12.6 mm and the residual spherical equivalent (SE) being -0.05 D. The selection of the ICL size was a key and difficult point for the pseudophakic eye due to the fact that the ACD enlarged after cataract surgery and IOL implantation. Therefore, the ACD of the left eye was a reference and the ICL size of right eye referred to that of the left eye. Then the power of the left eye was -10.5/+3.5/090, with the length being 12.6 mm and the residual SE being 0.00 D. The good position of ICL with ideal vault in the phakic eye suggests an accurate ICL size, then the ICL was implanted in the pseudophakic eye 1 week after the surgery of phakic eye.
Surgical Procedure
The medications used 3 days before surgery were the same as the standard implantation of the lens [6, 7]. After cycloplegic agents (1% Tropicamide, Alcon, Belgium) and topical anaesthesia (0.4% Oxybuprocaine hydrochloride, Santen, Japan), the visco surgical device (Provisc, Alcon, Belgium) was placed into the anterior chamber and synechiolysis of pupil was performed with surgical scissors carefully, then the implantation of ICL and the remaining procedure were the same as our previous studies [6, 7].
Follow-up
The surgeries were uneventful and no intraoperative complication was observed. Postoperatively, slitlamp examination of both eyes showed a quiet anterior chamber and that the ICL was in the sulcus with the IOL in the capsular bag. The manifest refraction of the right eye was +1.00 DS/-0.50 DC × 45 with UDVA 20/16 and CDVA 20/16. The manifest refraction of the left eye was +0.50 DS/-0.75 DC × 30 with UDVA 20/16 and CDVA 20/16. UBM showed the ICL V4c implanted in both eyes, the 4 ICL haptics of right eye were placed in supernasal, nasal, temporal and subtemporal ciliary crown, respectively. The 4 ICL haptics of left eye were placed in supertemporal, temporal, nasal and subnasal ciliary crown, respectively. All angles of both eyes were open (Fig. 3).
Three months after TICL V4c implantation, the refractive errors were +1.00 DS/-0.50 DC × 50 with UDVA 20/16 and CDVA 20/16 in the right eye, +0.75 DS/-0.75 DC × 45 with UDVA 20/16 and CDVA 20/13 in the left eye, respectively. The intraocular pressure, the vault and the endothelial cell density of the right and the left eye were 15.3 mmHg(R), 14.8 mmHg (L), 880 um(R), 530 um (L), 3125 cells/mm2(R), 3940 cells/mm2 (L), respectively (Table 2).
Discussion
Patients’ desire and their corneal conditions determine the options for correction of a refractive error. This patient had an urgent desire to get rid of the spectacles. Corneal refractive surgery is not an appropriate surgical correction for this patient because of his thin cornea. Lens replacement, on the other hand, is a difficult and risky surgical option because it has been a long time since the primary operation and that oval pupil with pupillary margin adhesion has been formed. Under the circumstances, ICL implantation has become the most appropriate choice.
Intraocular lens exchange for the correction of pseudophakic ametropia is feasible if the surgery is performed early. It would be difficult to replace an IOL into the bag, if anterior and posterior lens capsules were adhered to each other after a long-term primary surgery. Once the capsule shrinks around the IOL, complications such as capsule tear, vitreous loss, and retinal detachment may occur [2].
Corneal refractive surgery such as laser-assisted subepithelial keratomileusis (LASEK), laser-assisted in situ keratomileusis (LASIK) and small incision lenticule extraction (SMILE) is an option to correct pseudophakic ametropia [3, 4]. The procedures are irreversible and the incidence of complications such as flap complications and regression is well known. Lots of studies [8–10] report the ICL as a more favorable option than corneal refractive surgery in terms of higher stability and visual quality and its superior performance on dry eyes.
Implantation of supplementary lens for the correction of residual refractive error in pseudophakic eye is another option. Anterior chamber IOLs may cause endothelial cell loss and need a larger incision for insertion, as well as problems with pupil ovaling [11]. The technique of implanting 2 IOLs in the posterior chamber was described as “piggyback”, the traditional piggyback referred to that a conventional in-the-bag IOL was implanted in pseudophakic eye, which may cause interlenticular opacities because two IOL optics are placed close to each other [1, 12, 13]. Postoperatively, there were risks of intraocular pressure increase, IOL shift and pupil capture [12–14]. ICL compare favorably with IOL as the enough vault between the ICL and the primary IOL may contribute to decreasing the opacity [15–18]. Also, Toric ICL can correct the astigmatism. However, inappropriate ICL may cause TICL rotation or positioning error in pseudophakic eyes which can bring new astigmatism. Patients with severe vision loss or ghost after TICL rotation need adjustment of TICL position. The previous ICL V4 has a risk of postoperative intraocular pressure increase. At present, the ICL V4c decreases the rate of opacity and intraocular pressure increase without peripheral iridotomy for the central hole design [19]. Besides, pupil capture rarely occurs as the ICL haptics were placed in the ciliary sulcus. The accuracy of ICL is higher, because the calculation of ICL mainly depends on refraction, while the calculation of IOL mainly depends on the biometry parameters.
The option of ICL size is a problem for pseudophakic eyes. Both the ICL length evaluation and the power calculation were originally designed for phakic eyes, and it hasn’t been affirmed whether ICL would introduce significant error in pseudophakic eyes. Fortunately, the other phakic eye has not been implanted IOL and crystalline lens were reserved, and the parameters of the pseudophakic eye were similar with phakic eye except ACD. Therefore, the selection of ICL size in phakic eye was a reference to pseudophakic eye. Postoperatively, the ideal vault of both eyes was obtained. In the Takashi Kojima’s report [16], size of the ICL was chosen based on WTW and ACD, 6 eyes (75%) showed high vault (>3/2CT) after surgery, but scheimpflug image evaluation showed that the angle was open and the postoperative intraocular pressure was normal in these eyes with high vault. We believe that accurate ciliary sulcus diameter measured by UBM is necessary for the selection of ICL size. In general, the ACD of pseudophakic eye is far deeper than the phakic eye because the anterior surface of an IOL is situated further back in a pseudophakic situation than the that of the crystalline lens in a phakic situation. We advise that the ACD of phakic eye population may be a reference when choosing the size of ICL in pseudophakic eye if there was not a referable contralateral phakic eye.
Conclusions
Our case suggests that TICL V4c is safe, effective and predictable in managing pseudophakic ametropia.
Abbreviations
- ACD:
-
Anterior chamber depth
- CCT:
-
Central corneal thickness
- CDVA:
-
Corrected distance visual acuity
- DC:
-
Diopters cylinder
- DS:
-
Diopters sphericity
- ECD:
-
Endothelial cell density
- HSTS:
-
Horizontal sulcus to sulcus
- ICL:
-
Implantable collamer lens
- IOL:
-
Intraocular lens
- IOP:
-
Intraocular pressure
- L:
-
Left
- LASEK:
-
Laser-assisted subepithelial keratomileusis
- LASIK:
-
Laser-assisted in situ keratomileusis
- R:
-
Right
- SE:
-
Spherical equivalent
- SMILE:
-
Small incision lenticule extraction
- STS:
-
Sulcus to sulcus
- TICL:
-
Toric implantable collamer lens
- UBM:
-
Ultrasound biomicroscopy
- UDVA:
-
Uncorrected distance visual acuity
- VSTS:
-
Vertical sulcus to sulcus
- WTW:
-
White-to-white
References
Venter JA, Oberholster A, Schallhorn SC, Pelouskova M. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation. J Refract Surg. 2014;30:234–9.
Sinskey RM, Amin P, Stoppel JO. Indications for and results of a large series of intraocular lens exchanges. J Cataract Refract Surg. 1993;19:68–71.
Jin GJ, Merkley KH, Crandall AS, Jones YJ. Laser in situ keratomileusis versus lens-based surgery for correcting residual refractive error after cataract surgery. J Cataract Refract Surg. 2008;34:562–9.
Zaldivar R, Oscherow S, Piezzi V. Bioptics in phakic and pseudophakic intraocular lens with the Nidek EC-5000 excimer laser. J Refract Surg. 2002;18:S336–9.
Shimizu K, Kamiya K, Igarashi A, Shiratani T. Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia. Br J Ophthalmol. 2012;96:409–12.
Xun C, Miao H, Naidu RK, Xiaoying W, et al. Comparison of early changes in and factors affecting vault following posterior chamber phakic implantable collamer lens implantation without and with a central hole (ICL V4 and ICL V4c). BMC Ophthalmol. 2016;16:161.
Xun C, Xiaoying W, Zhang X, Zhi C, Xingtao Z. Implantable collamer lens for residual refractive error after corneal refractive surgery. Int J Ophthalmo. 2016;9(10):1421–6.
Kamiya K, Igarashi A, Shimizu K, Matsumura K, Komatsu M. Visual performance after posterior chamber phakic intraocular lens implantation and wavefront-guided laser in situ keratomileusis for low to moderate Myopia. Am J Ophthalmol. 2012;153:1178–1186.e1.
Igarashi A, Kamiya K, Shimizu K, Komatsu M. Visual performance after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis for high Myopia. Am J Ophthalmol. 2009;148:164–170.e1.
Sanders DR. Matched population comparison of the Visian Implantable Collamer Lens and standard LASIK for myopia of -3.00 to -7.88 diopters. J Refract Surg. 2007;23:537–53.
Baikoff G, Colin J. Damage to the corneal endothelium using anterior chamber intraocular lenses for myopia. Refract Corneal Surg. 1990;6:383.
Kahraman G, Amon M. New supplementary intraocular lens for refractive enhancement in pseudophakic patients. J Cataract Refract Surg. 2010;36:1090–4.
Gerten G, Kermani O, Schmiedt K, Farvili E, Foerster A, Oberheide U. Dual intraocular lens implantation: Monofocal lens in the bag and additional diffractive multifocal lens in the sulcus. J Cataract Refract Surg. 2009;35:2136–43.
Gayton JL, Sanders V, Van Der Karr M. Pupillary capture of the optic in secondary piggyback implantation. J Cataract Refract Surg. 2001;27:1514–5.
Eissa SA. Management of pseudophakic myopic anisometropic amblyopia with piggyback Visian(R) implantable collamer lens. Acta Ophthalmol. 2016;95:188–93.
Kojima T, Horai R, Hara S, et al. Correction of residual refractive error in pseudophakic eyes with the use of a secondary piggyback toricImplantable Collamer Lens. J Refract Surg. 2010;26:766–9.
Hsuan JD, Caesar RH, Rosen PH, Rosen ES, Gore CL. Correction of pseudophakic anisometropia with the Staar Collamer implantable contact lens. J Cataract Refract Surg. 2002;28:44–9.
Chiou AG, Bovet J, de Courten C. Pseudophakic ametropia managed with a phakic posterior chamber intraocular lens. J Cataract Refract Surg. 2001;27:1516–8.
Huseynova T, Ozaki S, Ishizuka T, Mita M, Tomita M. Comparative study of 2 types of implantable collamer lenses, 1 with and 1 without a central artificial hole. Am J of Ophthalmol. 2014;157:1136–43.
Acknowledgments
We adhered to the CARE guidelines/methodology.
Funding
This research was supported by the Committee of Science and Technology of Shanghai, China (Grant No. 09411962100), the Health and Family Planning Committee of Pudong New District of Shanghai, China (Grant No. PW2014D-1).
Availability of data and materials
Data and materials are available upon request from the corresponding author at doctxiaoyingwang@163.com.
Authors’ contributions
Literature screening and selection was performed by XC. XW and XZ collected and interpreted the data. XC carried out the statistical analysis. XC drafted the manuscript. XW and XZ revised and reviewed of the manuscript. XC, XW and XZ gave final approval of the version to be published. All authors have read and approved it for publication.
Competing interests
The authors declare that they have no competing interests.
Consent for publication
Written informed consent was obtained from the patient for publication of this case report and any accompanying images.
Ethics approval and consent to participate
Not applicable.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Chen, X., Wang, X. & Zhou, X. Pseudophakic ametropia management with toric implantable collamer lens with a central hole (case report). BMC Ophthalmol 17, 17 (2017). https://doi.org/10.1186/s12886-017-0414-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12886-017-0414-6
Keywords
- Implantable collamer lens
- TICL V4c
- Pseudophakic ametropia
- Case report