Long-term results of glaucoma drainage device surgery

Abstract

Background

To evaluate long-term results of eyes with glaucoma drainage device (GDD).

Methods

We retrospectively reviewed medical records of all patients who underwent GDD placement at our institution between 2001 and 2014. A total of 110 eyes of 90 patients were studied. Glaucoma outcome was assessed by postoperative intraocular pressure (IOP), number of medications, and need for further glaucoma surgery. Surgical procedures before and during the study period, and their complications were evaluated.

Results

The mean follow-up was 78.3 ± 44.0 months. The mean preoperative intraocular pressure was 30.8 ± 6.9 mmHg with 3.5 ± 1.1 glaucoma medications. At last postoperative follow-up, the mean IOP decreased to 14.3 ± 5.4 mmHg with 1.6 ± 1.5 glaucoma medications. GDD implantation successfully controlled glaucoma in 86, 85, 81, 78, 79, 76 and 73% of eyes at 1, 2, 3, 4, 5, 7 and 10 years, respectively. At last follow-up IOP was successfully controlled in 67% of eyes. Clinical complications occurred in 56.4% of eyes during the follow-up period.

Conclusions

A glaucoma drainage device can successfully control intractable glaucoma even after a very long period of time.

Peer Review reports

Background

Glaucoma is a leading cause of blindness worldwide [1]. Intraocular pressure (IOP) lowering is the only proven method to prevent the development [2] and/or slow the progression of glaucomatous optic neuropathy [3]. The conventional approach is to attempt medical therapy or laser trabeculoplasty prior to surgery.

Recently, the use of glaucoma drainage devices (GDDs) has become a widely used therapy option for the management of eyes with complicated glaucoma refractory to standard trabeculectomy with adjunctive antifibrotics. This trend is following the results of the Tube Versus Trabeculectomy study, which reported a better success rate at 5 years with Baerveldt implantation than with trabeculectomy with mitomycin-C in patients who had undergone previous surgery [4].

Since Molteno’s introduction in 1969 different modified types of drainage devices, which differ in surface area, shape, composition, and presence or absence of a flow-restricting valve are currently used [5]. Two of the most common devices are the valved Ahmed Glaucoma Valve (AGV; New World Medical, Rancho Cucamonga, CA, USA) and the non-valved Baerveldt Glaucoma Implant (BGI; Abbott Medical Optics, Abbott Park, IL, USA). These devices have been shown to be effective in lowering IOP for the treatment of glaucoma in patients with a variety of glaucomas in whom medical therapy or multiple trabeculectomies have failed or are expected to have a very low chance of surgical success [6,7,8,9]. The surgical success rates are dependent on the length of follow-up, success criteria, and different types of glaucoma. They vary from 68 to 100% for the Ahmed Glaucoma Valve and from 43 to 100% for the Baerveldt Glaucoma Implant [5].

In this study, we present long-term follow-up results of eyes with glaucoma drainage device. In addition, all relevant clinical factors were evaluated for their association with glaucoma outcome.

Methods

The medical records of all patients who underwent GDD placement (Baerveldt or Ahmed) at the Department of Ophthalmology of the University Medical Center Schleswig-Holstein Campus Kiel between 2001 and 2014 were retrospectively reviewed. Patients who underwent a penetrating keratoplasty prior to GDD implantation were excluded.

One hundred ten eyes of 90 patients were included in this study. Study criteria required a minimum of 2-year follow-up. Collected data included demographic information, type of glaucoma, type of corneal pathology, number and type of previous ophthalmic surgeries, complications, preoperative and postoperative best-corrected visual acuity, preoperative and postoperative IOP, number and type of glaucoma medications. Surgical outcome was assessed in terms of adequacy of IOP control. Success for glaucoma control was defined as a postoperative IOP ≥ 5 mmHg and ≤ 21 mmHg with or without application of antiglaucoma medications, with no need for further glaucoma surgery and without loss of light perception at last follow-up. Combination medication eye drops were counted as 2 medications. An oral carbonic anhydrase inhibitor was counted as 1 additional medication. Visual acuity was measured with the Snellen vision chart. For numerical analysis, Snellen visual acuity was converted to logarithm of the minimum angle of resolution (logMAR) values using the equitation: logMAR = ─log (visual fraction).

Surgical technique

All glaucoma surgical procedures were carried out by the same experienced surgeon (B. N.) of the Department of Ophthalmology. GDDs used in this study were Ahmed™ Glaucoma Valve (FP7 AGV; New World Medical, Rancho Cucamonga, CA, USA) and Baerveldt (250 mm2 BGI; Abbott Medical Optics, Abbott Park, IL, USA). The surgical techniques of GDD implantation have been decribed in detail by others before [10, 11]. Briefly, a limbus based conjunctival peritomy was done with a blunt dissection down to bare sclera in 2 to 3 quadrants. Implants were placed between the lateral rectus and the superior rectus if possible. For Baerveldt implants a 7–0 vicryl ligature suture was placed to form a watertight seal around the tube. GDD plates were secured to sclera with 7–0 prolene sutures. A limbal tract was created with a 23-gauge needle. Then a prompt insertion of the tube through insertion forceps was performed. Tubes were inserted into the anterior chamber just overlying the iris without touching the cornea. In eyes where the tube was positioned in the pars plana, a pars plana vitrectomy (PPV) was performed. A scleral fistula was created 3.0 to 3.5 mm posterior to the corneoscleral limbus using a 22- or 23-gauge needle directed parallel to the iris plane. In cases of anterior chamber tube positioning the tube was placed within the sclera, for about one third of its length. Therefore no xenogeneic or other tissue was used for coverage. Tubes were secured to the sclera with 1–3 interrupted 10–0 nylon sutures. The conjunctiva and Tenon’s tissue were sutured in single layer using 8–0 vicryl sutures. At the end of GDD surgery no leakage was observed in any of the eyes. A subconjunctival injection of dexagentamicin was given at the end of surgery. Postoperative topical medications included antibiotics and corticosteroids depending on the degree of intraocular inflammation. The medication was tapered to a low dose over several months. If necessary, glaucoma medications were added to control IOP.

Statistical analysis

The statistical analyses were performed using the SPSS software (IBM SPSS Statistics, Version 24). Univariate analysis was performed using the log-rank test for comparing Kaplan-Meier survival curves. For preoperative and postoperative analyses, the Wilcoxon signed-rank test, and the Wilcoxon rank sum test (U-test) were used for measured data. The Fisher exact test was used for nominal scaled data. A p-value less than 0.05 was considered statistically significant.

Results

A total of 110 eyes of 90 patients were included. The demographic data and preoperative clinical characteristics of the study patients are presented in Table 1. The mean patient age was 47.9 ± 24.4 years (range, 2–87). The mean follow-up was 78.3 ± 44.0 months (range, 24–193). Glaucoma diagnoses were divided into different types.

Table 1 Patient Demographic Data

One hundred one (91.8%) Ahmed implants and 9 (8.2%) Baerveldt implants were used. Eighty-three (75.5%) implants were placed in the anterior chamber, and 27 (24.5%) implants were positioned in the pars plana. The number of performed surgical procedures before the study period was 2.7 ± 1.4 (Table 1). During the study period the number of additionaly performed surgical procedures was 1.5 ± 1.4 (Table 3).

Glaucoma outcome

The mean preoperative intraocular pressure was 30.8 ± 6.9 mmHg. At last postoperative follow-up, the mean IOP had decreased to 14.3 ± 5.4 mmHg (p = 0.001) (Fig. 1). The mean preoperative glaucoma medications were 3.5 ± 1.1. The mean glaucoma medications were 1.1 ± 1.2, 1.1 ± 1.2, 1.5 ± 1.3, 1.6 ± 1.4, 1.9 ± 1.6, 1.8 ± 1.7, 1.8 ± 1.6 at 1, 2, 3, 4, 5, 7 and 10 years, respectively. At last postoperative follow-up, the mean glaucoma medications were 1.6 ± 1.5 (p = 0.001) (Table 2). Overall, GDD implantation successfully controlled glaucoma in 86, 85, 81, 78, 79, 76 and 73% of eyes at 1, 2, 3, 4, 5, 7 and 10 years, respectively. At last follow-up IOP was successfully controlled in 67% of eyes. The success rate of the Ahmed implant was 68%, and of the Baerveldt implant 56% at last follow-up. However, this difference was not statistically significant (p = 0.47).

Fig. 1
figure 1

Kaplan-Meier survival analysis of IOP (intraocular pressure)

Table 2 Postoperative Data

In terms of tube placement, the glaucoma success rate of the anterior chamber tube placement was 64%, and of the pars plana tube placement 78% at last follow-up. No statistically significant difference in success rates was observed (p = 0.56). The overall survival of glaucoma outcome was analyzed with a Kaplan-Meier curve (Fig. 2).

Fig. 2
figure 2

Overall Kaplan-Meier survival analysis of glaucoma success throughout follow-up

Visual acuities

Each patient’s preoperative visual acuity was compared with the visual acuity at the last follow-up. The mean pre-GDD visual acuity (in logMAR) was 0.7 ± 0.6. At last postoperative follow-up, the mean visual acuity (logMAR) decreased to 0.9 ± 0.7 (p = 0.002) (Table 2). In a comparision of visual acuitiy between first and last visits, 33 (30%) eyes showed improvement, 20 (18%) eyes had no change, and 57 (52%) worsened. Of these 57 eyes where the visual acuity decreased, 20 (35%) eyes had a corneal decompensation.

Complications

Clinical complications occurred in 62 (56.4%) eyes during the follow-up period. Postoperative complications included corneal decompensation (n = 20, 19%), encapsulated bleb (n = 27, 24.5%), retinal detachment (n = 7, 6.4%), GDD or tube dislocation (n = 7, 6.4%), tube erosion (n = 7, 6.4%), tube-endothelial touch or blockage (n = 5, 4.5%), chronic hypotony (n = 5, 4.5%), and phthisis bulbi (n = 4, 3.6%). Table 3 shows complications during follow-up. Overall, the rate of complications was not dependent on the tube placement (p = 0.5).

Table 3 Additional Procedures and Complications

Five eyes had a corneal decompensation prior to GDD implantation. That is why these eyes were excluded from the statistical analysis of postsurgical corneal decompensation (2 eyes with anterior chamber tube placement, and 3 eyes with pars plana tube placement). During follow-up period corneal decompensation ocurred in 18 of 81 eyes (22%) with anterior chamber tube placement, and only in 2 of 24 eyes (8%) with pars plana tube placement (p = 0.15). At 2-year follow-up, there was a trend towards increased corneal decompensation in eyes with anterior chamber tube placement compared to pars plana tube placement (p = 0.076). From the third year of the study, no difference was observed between both groups (p = 0.14) (Fig. 3). Due to the fact that eyes with pars plana tube placement had a shorter follow-up (up to 108 months), we only compared the corneal decompensation associated with tube placement over a shorter period.

Fig. 3
figure 3

Kaplan-Meier survival analysis of corneal clarity throughout follow-up

Surgical procedures during study period

During the study period the number of additional surgical procedures was 1.5 ± 1.4 (Table 3). The most commonly performed additional glaucoma procedures during the follow up period were needling of filtering bleb/5-FU injections (n = 27), keratoplasty (n = 20), tube shortening/revision (n = 16), and implantation of additional GDD (n = 12). Overall, reoperations for complications during the follow-up were not dependent on the tube placement (p = 0.16). Surgical complications an additional glaucoma procedures are shown in Table 3.

Discussion

Glaucoma drainage devices are commonly used to lower IOP in patients with difficult glaucomas either as a primary surgical option or after failure of conventional filtration procedures [12, 13]. A growing experience with these devices, improvements in the material design and surgical techniques for performing GDD implantation have also led to increased utilization in recent years [14]. Data of recently published studies, which observed the efficacy of GDDs contribute to a paradigm shift in glaucoma treatment. The TVT study shows a persistent treatment benefit of tube shunt surgery over trabeculectomy through 5 years of follow-up. At 5 years, the cumulative probability of failure was 29.8% in the tube group and 46.9% in the trabeculectomy group [4]. The results from our study demonstrated overall a cumulative probability of glaucoma failure of 21% through 5 years of follow-up. In contrast to the TVT study, which used Baerveldt implants, in our series only 9 patient received a Baerveldt implant. All other patients had an Ahmed implantation. Due to the fact that our study did not include enough patients with Baerveldt implants, it was difficult to compare the efficacy of both implants.

Three year results of the ABC study [6] demonstrated a cumulative probability of failure of 31.3% in the AGV group, and of 32.1% in the BGI group. At 3 years, the AVB study [9] reported a failure rate of 51% in the AGV group and of 34% in the BGI group. In our study, patients who received the Ahmed implant showed a failure rate of 20%, patients who received the Baerveldt implant showed a failure rate of 11% after a 3 year follow-up. The cumulative probabilty of failure for both implants was 19% at 3 year follow-up.

At 5 years of follow-up, the ABC study observed a cumulative probability of failure of 44.7% in the AGV group, and of 39.4% in the BGI group [6]. In our study, patients who received the Ahmed implant showed a failure rate of 22%, patients who received the Baerveldt implant showed a failure rate of 11% after a 5 year follow-up. The cumulative probabilty of failure for both implants was 21% at 5 year follow-up. At last follow-up of 78.3 ± 44.0 months, a failure of glaucoma outcome occurred in 32% of eyes.

Rososinski et al. evaluated outcomes of pars plana versus anterior chamber placement of Baerveldt implants (anterior chamber tube placement in 34 eyes, pars plana tube placement in 29 eyes) [15]. They reported a qualified success rate at 2 years of 94% for the pars plana group and of 91% for the anterior chamber group [15]. In our study (anterior chamber tube placement in 83 eyes, pars plana tube placement in 27 eyes), the success rate at 2 years was 78% for the pars plana group, and 88% for the anterior chamber group (p = 0.22).

Guzman et al. examined the outcomes of glaucoma drainage devices (33 eyes, Molteno and Baerveldt tubes) inserted into the pars plana. They described a qualified success rate of 42.4% at 30 months [16]. In our study (27 eyes with pars plana tube placement), the success rate at 3 years was 78%. At last follow-up of 78.3 ± 44.0 months, our results of eyes with tubes placed in the pars plana showed IOP control in 78%, and in eyes with anterior chamber tube placement in 64%, respectively (p = 0.56).

Christiakis et al. reported a postoperative complication rate of 52% at 3 year follow-up [9]. At last follow-up, we found a postoperative complication rate of 56%. Rososinski et al. described no case of corneal decompensation or corneal graft failure in eyes with pars plana Baerveldt tube implantation during their 2 year follow-up period [15]. The results from our study demonstrated a corneal decompensation in 1 of 27 eyes (4%) with pars plana Baerveldt or Ahmed tube implantation. Souza et al. experienced the complication of failed penetrating corneal keratoplasty during the 5 year follow-up period in 5% (4 eyes) after anterior chamber Ahmed implantation [17]. In our study, at 5 years follow-up corneal decompensation occured in 19%. Overall in our study, no difference was observed between eyes with anterior chamber tube placement compared to pars plana tube placement. Eyes with pars plana tube placement had a shorter follow-up. Therefore, we could only compare the tube placement over a shorter period.

There are some limitations to our study. The major limitation is its retrospective design. Further limitations are the inclusion of patients with various glaucoma diagnoses and variable severity of disease, variety of used GDDs, and different locations for the tube placement.

However, it is important to note that the sample size of this study is comparatively large. Furthermore, all surgical procedures were performed by the same surgeon. This study has a remarkably long follow-up period, which allows an assessment of long-term outcome.

Conclusions

Our study provides long-term follow-up outcomes of patients with glaucoma drainage devices. Overall, our data show that the glaucoma success with the tube implant was high. A glaucoma drainage device placement can provide effective glaucoma control even after a very long period of time.

Abbreviations

5-FU:

5-fluorouracil

ABC study:

Ahmed Baerveldt Comparison Study Group

AGV:

Ahmed glaucoma valve

AVB study:

Ahmed versus Baerveldt study

BGI:

Baerveldt glaucoma implant

DSAEK:

Descemet’s stripping automated endothelial keratoplasty

GDD:

Glaucoma drainage device

IOP:

Intraocular pressure

logMAR:

Logarithm of the minimum angle of resolution

mmHg:

Millimetre (s) of mercury

PCIOL:

Posterior chamber intraocular lens

PKP:

Penetrating keratoplasty

ppV:

Pars plana vitrectomy

TVT study:

Tube Versus Trabeculectomy study

VA:

Visual acuity

References

  1. Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol. 2006;90:262–7.

    Article  CAS  Google Scholar 

  2. Kass MA, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, et al. The ocular hypertension treatment study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120:701–13.

    Article  Google Scholar 

  3. Leske MC, Heijl A, Hyman L, Bengtsson B, Dong L, Yang Z, et al. Predictors of long-term progression in the early manifest glaucoma treatment trial. Ophthalmology. 2007;114:1965–72.

    Article  Google Scholar 

  4. Gedde SJ, Singh K, Schiffman JC, Feuer WJ. Tube versus trabeculectomy study group. The tube versus trabeculectomy study: interpretation of results and application to clinical practice. Curr Opin Ophthalmol. 2012;23:118–26.

    Article  Google Scholar 

  5. Schwartz KS, Lee RK, Gedde SJ. Glaucoma drainage implants: a critical comparison of types. Curr Opin Ophthalmol. 2006;17:181–9.

    Article  Google Scholar 

  6. Budenz DL, Barton K, Gedde SJ, Feuer WJ, Schiffman J, et al. Ahmed Baerveldt comparison study group. Five-year treatment outcomes in the Ahmed Baerveldt comparison study. Ophthalmology. 2015;122(2):308–16.

    Article  Google Scholar 

  7. Tsai JC, Johnson CC, Kammer JA, Dietrich MS. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma II: longer-term outcomes from a single-surgeon. Ophthalmology. 2006;113:913–7.

    Article  Google Scholar 

  8. Wang JC, See JL, Chew PT. Experience with the use of Baerveldt and Ahmed glaucoma drainage implants in an Asian population. Ophthalmology. 2004;111:1383–8.

    Article  Google Scholar 

  9. Christiakis PG, Tsai JC, Kalenak JW, Zurakowski D, Cantor LB, Kammer JA, et al. Ahmed II. The Ahmed versus Baerveldt study: three-year treatment outcomes. Ophthalmology. 2013;120(11):2232–40.

    Article  Google Scholar 

  10. Sidoti PA, Mosny AY, Ritterband DC, Seedor JA. Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. Ophthalmology. 2001;108:1050–8.

    Article  CAS  Google Scholar 

  11. Lloyd MA, Baerveldt G, Heuer DK, Minckler DS, Martone JF. Initial clinical experience with the Baerveldt implant in complicated glaucomas. Ophthalmology. 1994;101:640–50.

    Article  CAS  Google Scholar 

  12. Fechtner RD, Singh K. Maximal glaucoma therapy. J Glaucoma. 2001;10:S73–5.

    Article  CAS  Google Scholar 

  13. Assaad MH, Baerveldt G, Rockwood EJ. Glaucoma drainage devices: pros and cons. Curr Opin Ophthalmol. 1999;10:147–53.

    Article  CAS  Google Scholar 

  14. Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL. Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004. Ophthalmology. 2007;114:2265–70.

    Article  Google Scholar 

  15. Rososinski A, Wechsler D, Grigg J. Retrospective review of pars plana versus anterior chamber placement of Baerveldt glaucoma drainage device. J Glaucoma. 2015;24(2):95–9.

    Article  Google Scholar 

  16. DeGuzman MHPU, Valencia A, Farinelli AC. Pars plana insertion of glaucoma drainage devices for refractory glaucoma. Clin Exp Ophthalmol. 2006;34:102–7.

    Article  Google Scholar 

  17. Souza C, Tran DH, Loman J, Law SK, Coleman AL, Caprioli J. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol. 2007;144(6):893–900.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

We acknowledge financial support by Land Schleswig-Holstein within the funding programme Open Access Publikationfonds.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

All authors have participated directly in planning and execution of the work and have approved the final version of the manuscript. KP: acquisition and analysis of data, drafting and writing the article; MS: acquisition of data, final approval; FT: participated in the data collection and analysis; JR: participated in the design of the study and revised the article critically for important intellectual content; BN conception and design, helped to draft the manuscript.

Corresponding author

Correspondence to Konstantine Purtskhvanidze.

Ethics declarations

Ethics approval and consent to participate

This study adhered to the tenets of the Declaration of Helsinki. For this retrospective type of study formal consent is not required according the regulations of the IRB Universitiy Medical Center Schleswig-Holstein.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Purtskhvanidze, K., Saeger, M., Treumer, F. et al. Long-term results of glaucoma drainage device surgery. BMC Ophthalmol 19, 14 (2019). https://doi.org/10.1186/s12886-019-1027-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-019-1027-z

Keywords