Descemet’s membrane endothelial keratoplasty for pseudoexfoliation syndrome: a case series

Abstract

Background

To evaluate the clinical outcomes and features of Descemet’s membrane endothelial keratoplasty (DMEK) for eyes with pseudoexfoliation syndrome (PEX).

Methods

In this retrospective study, 37 DMEK cases were reviewed from available medical records. Patients who exhibited endothelial dysfunction derived from PEX or Fuchs endothelial corneal dystrophy (FECD) and successfully underwent cataract surgery about four weeks before DMEK were enrolled. The best spectacle-corrected visual acuity (BSCVA), central corneal thickness (CCT), endothelial cell density (ECD), and incidence of intra-operative/post-operative complications of DMEK were analyzed.

Results

This study included 14 eyes of 14 patients (PEX: n = 6, FECD: n = 8). There was no primary graft failure. In the PEX group, BSCVA improved from 0.67 ± 0.28 at the preoperative point to 0.43 ± 0.14 at 1 month, 0.27 ± 0.10 at 3 months, and 0.19 ± 0.08 at 6 months after DMEK. The donor corneal ECD was 2704 ± 225 cells/mm2 at the preoperative point and decreased to 1691 ± 498 cells/mm2 at 1 month, 1425 ± 366 cells/mm2 at 3 months, and 1281 ± 340 cells/mm2 (52.7 ± 11.7% less than ECD of the donor graft) at 6 months after DMEK. None of the patients required rebubbling. When compared with the FECD group, no statistical difference was observed in CCT (p = 0.821); BSCVA (p = 0.001) and the reduction rate of ECD (p = 0.010) were relatively worse.

Conclusions

DMEK is effective for the treatment of endothelial dysfunction due to PEX.

Peer Review reports

Background

Corneal transplantation is a common procedure. Well over 100,000 cases are performed annually worldwide. About half of all corneal transplantations involve endothelial keratoplasty, which replaces the corneal endothelium with a monolayer of cells. Descemet membrane endothelial keratoplasty (DMEK) is a corneal endothelial keratoplasty newly introduced by Melles et al. that allows for a faster recovery of visual acuity, fewer higher-order aberrations, and lower immunological rejection rates compared to conventional penetrating keratoplasty such as Descemet’s stripping automated endothelial keratoplasty (DSAEK) [1,2,3,4].

With the worldwide increase in number of DMEK surgeries, many papers regarding DMEK for Fuchs endothelial corneal dystrophy (FECD) have been published. However, other causes of corneal endothelial dysfunction, such as complications from cataract surgery (pseudophakic bullous keratopathy) and endotheliopathy in pseudoexfoliation syndrome (PEX), are poorly understood [5].

PEX is a genetically determined, age-related, and environmentally influenced disorder characterized by anomalous production and accumulation of abnormal fibrillar extracellular aggregates on anterior segment structures, most notably on the lens capsule and pupillary border of the iris [6,7,8]. The exfoliative material is often expressed as grey-white and dandruff-like, but its origin is still obscure [9]. The material is observed in multiple organs such as the heart, lung, liver, kidney, cerebral meninges and blood vessels [10, 11]. It is also observed in ocular structures such as the anterior capsule, iris, lens zonule, trabecular meshwork and corneal endothelium. It is the leading cause of glaucoma, cataracts, and bullous keratopathy (BK) [12,13,14].

Evidence has accumulated reporting the morphological alterations in almost all cell layers of the cornea in eyes with PEX. Eyes with PEX have been documented to have deposition of hyper reflective material on the endothelium, which is presumed to be PEX material, and to have significantly lower cell densities in the basal epithelium, anterior and posterior stromatolites, and endothelium compared to controls [15]. PEX can lead to corneal endothelial cell decompensation, which can result in severe BK, requiring keratoplasty [13].

To our knowledge, this is the first paper to focus on keratoplasty for PEX. Here we describe a case series in which we conduct DMEK for BK derived from PEX and compare the result with that derived from FECD.

Methods

Patients and examinations

We complied all ethical principles within the Declaration on Helsinki, and we were approved for the surgical maneuvers and evaluation protocols used in this retrospective study by the Institutional Review Board of Yokohama Minami Kyosai Hospital (Approval no. YKH_30_02_08). We obtained informed consent in written style by patients with endothelial dysfunction derived from PEX or FECD and cataract, and they enrolled this study. The diagnosis of PEX keratopathy was confirmed clinically as well as electron microscopy. Eyes in the PEX group had accumulation of exfoliative materials that was characteristic of PEX and didn’t have other findings, such as guttata and history of past complicated cataract surgery, that could cause BK. Between April 1, 2016, and December 31, 2017, at the department of ophthalmology of Yokohama Minami Kyosai Hospital in Kanagawa, Japan, a total of 37 surgeries were applicable to the study and 14 eyes of 14 patients (6 males and 8 females) were considered eligible. Six eyes revealed PEX syndrome (PEX group), and the other 8 eyes revealed FECD (FECD group).

We performed tests preoperatively and up to 6 months after DMEK. The inspection items were standard ophthalmic examinations, best spectacle-corrected visual acuity (BSCVA), central corneal thickness (CCT), and corneal endothelial cell density (ECD). We also checked corneal endothelial characteristics, graft adaptation and complications after DMEK. CCT was measured using anterior segment optical coherence tomography (AS-OCT, SS1000, Tomey, Aichi, Japan). Preoperative ECDs were derived from the donor eye bank records and postoperative ECDs were measured with the aid of specular microscope (FA3509, Konan Medical, Hyogo, Japan). A form of endothelial cells was measured with the specular microscope, graft adaptation was measured with slit-lamp microscopy and AS-OCT, and clinical/subclinical cystoid macular edema (CME) was measured with spectral-domain OCT (RS 3000, Nidek, Aichi, Japan). CME was confirmed as the presence of intraretinal fluid spaces seen in the fovea region using spectral-domain OCT.

Cataract surgery

Cataract surgery was scheduled about 4 weeks before DMEK. It was performed under sub-Tenon anesthesia. The pupil was preoperatively treated with a mydriatic agent (0.5% tropicamide and phenylephrine hydrochloride; Mydrin-P; Santen, Japan) to achieve mydriasis. Maximum pre-operative pupil dilation was noted. Phacoemulsification was performed, and the foldable intraocular lens (IOL) was placed in the bag. Five PEX-syndrome patients who needed transscleral-sutured IOL implantation due to zonular dialysis were excluded from this study.

Surgical procedure of DMEK

A punch was placed on the endothelial surface of the donor disc to indent a circle 7.75, 8.0, or 8.25 mm in diameter. The donor grafts were peeled after staining with 0.1% Brilliant Blue G (BBG) 250 (BBG; Sigma-Aldrich, St. Louis, MO, USA) (1.0 mg/mL). 1.0- and 1.5-mm-diameter dermatological biopsy punches (Kai Industries, Seki, Japan) were used to place asymmetric marks on the edges of the grafts to indicate graft orientation [16]. Donor grafts were cut using the donor punch, stained with 0.1% BBG for 1 min, placed in a balanced salt solution (BSS) (BSS-plus; Alcon, Osaka, Japan) for about 30 min, and used for insertion [17].

All surgeries were performed under retrobulbar block and Nadbath facial nerve block. Two paracenteses and a 2.8-mm upper corneal or corneoscleral tunnel were made for the recipient cornea. Peripheral iridotomy was performed at the 6-o’clock position using a 25-gauge vitreous cutter to prevent the occurrence of a postoperative pupillary block. After the central recipient descemetorhexis under air, the donor membrane graft was inserted into the anterior chamber using an IOL injector (model WJ-60 M; Santen Pharmaceuticals, Osaka, Japan) [5].

The inserted graft was unfolded via a no-touch technique with shallowing of the anterior chamber [18]. After confirmation of the correct orientation of the graft, the anterior chamber was filled with air and partially replaced with BSS 15 min later. Finally, 0.4 mg of betamethasone (Rinderon; Shionogi, Osaka, Japan) was subconjunctivally injected and 1.5% (w/v) levofloxacin eye drops (Cravit; Santen Pharmaceuticals) was administered.

Postoperatively, 1.5% (w/v) levofloxacin (Cravit), 0.1% (w/v) betamethasone sodium phosphate (Sanbetasone; Santen Pharmaceuticals), and 2% (w/v) rebamipide ophthalmic solution (Mucosta; Otsuka, Tokyo, Japan) were prescribed four times daily for 3 months and tapered thereafter.

Statistical analysis

Male/female and right/left ratios were compared using the χ2 test. The paired t-test was used to compare preoperative and postoperative values and the unpaired t-test was used to compare the PEX group and the FECD group. Moreover, multiple regression analysis was performed after the age adjustment. All analyses were performed using JMP 13.2.0 (SAS institute inc., Cary NC, USA). A P-value of< 0.05 was considered to be statistically significant.

Results

Patients

The preoperative patient profiles are summarized in Table 1. As shown in Additional file 1: Figure S1, even in PEX patients with severe corneal edema, the cornea edema disappeared and a completely clear cornea was obtained after cataract surgery and DMEK. The mean age of the PEX group was 79.7 ± 5.1 (from 75 to 85 years old); that of the FECD group was 70.4 ± 8.6 (from 55 to 81 years old). The mean age of the PEX group was significantly higher than that of the FECD group (p = 0.037). Preoperative BSCVA and CCT before cataract surgery were not significantly different between the PEX and FECD groups (BSCVA; p = 0.492, CCT; p = 0.710). Preoperatively, none of them was diagnosed a secondary open angle glaucoma (SOAG) with optic nerve damage. The mean pupil diameter was smaller in the PEX group than in the FECD group (p = 0.018) and 3 eyes of the PEX group were used capsule expanders due to their zonular weakness at the cataract surgeries. All cataract surgeries were uneventful.

Table 1 Patient characteristics before surgery

Visual acuity

In the PEX group, BSCVA improved from 0.67 ± 0.28 at the preoperative point to 0.43 ± 0.14 at 1 month, 0.27 ± 0.10 at 3 months, and 0.19 ± 0.08 at 6 months after DMEK. In the FECD group, BSCVA improved from 0.78 ± 0.29 at the preoperative point to 0.21 ± 0.21 at 1 month, 0.11 ± 0.15 at 3 months, and 0.017 ± 0.074 at 6 months. A statistically significant improvement of BSCVA was obtained in both groups at all examination points except at 1 month in the PEX group (p = 0.077 at 1 month, 0.009 at 3 months, 0.003 at 6 months in the PEX group; p = 0.005 at 1 month, p < 0.001 at 3 and 6 months in the FECD group, the paired t-test used in both groups). BSCVA was not significantly different between the two groups at the preoperative point (p = 0.492). However, the BSCVA of the PEX group became significantly worse than that of the FECD group postoperatively (p = 0.047 at 1 month, p = 0.049 at 3 months, p = 0.001 at 6 months, respectively) (Fig. 1).

Fig. 1
figure 1

Changes in best spectacle-corrected visual acuity. A statistically significant improvement of BSCVA is obtained in the pseudoexfoliation syndrome (PEX) group except at 1 month (p = 0.077 at 1 month, 0.009 at 3 months, 0.003 at 6 months; paired t-test). A statistically significant improvement of BSCVA is also obtained in the Fuchs endothelial corneal dystrophy (FECD) group at all examination points (p = 0.005 at 1 month, p < 0.001 at 3 and 6 months; paired t-test). There is no significant difference between the two groups at the preoperative point (p = 0.492), whereas the PEX group is significantly worse than the FECD group postoperatively (p = 0.047 at 1 month, p = 0.049 at 3 months, p = 0.001 at 6 months; unpaired t-test)

Central corneal thickness

In the PEX group, CCT changed from 657.3 ± 61.1 μm at the preoperative point to 523.2 ± 34.6 μm at 1 month, 489.7 ± 32.5 μm at 3 months, and 488.3 ± 30.1 μm at 6 months after DMEK. In the FECD group, CCT changed from 669.1 ± 54.6 μm at the preoperative point to 494.4 ± 48.6 μm at 1 month, 486.6 ± 31.8 μm at 3 months, and 492.3 ± 32.3 μm at 6 months. A statistically significant improvement of CCT was obtained in both groups at all examination points (p = 0.002 at 1 month, 0.002 at 3 months, p < 0.001 at 6 months in the PEX group; p = 0.001 at 1 month, p < 0.001 at 3 and 6 months in the FECD group, the paired t-test used in both groups), and there was no significant difference between the two groups at all examination points (p = 0.71 preoperatively, 0.24 at 1 month, 0.86 at 3 months, 0.82 at 6 months; Fig. 2).

Fig. 2
figure 2

Changes in central corneal thickness. A statistically significant improvement of central corneal thickness (CCT) is obtained in the pseudoexfoliation syndrome (PEX) group at all examination points (p = 0.002 at 1 month, 0.002 at 3 months, p < 0.001 at 6 months; paired t-test). A statistically significant improvement of CCT is also obtained in the Fuchs endothelial dystrophy (FECD) group at all examination points (p = 0.001 at 1 month, p < 0.001 at 3 and 6 months; paired t-test). There is no significant difference between the two groups at all examination points (p = 0.71 preoperatively, 0.24 at 1 month, 0.86 at 3 months, 0.82 at 6 months; unpaired t-test)

Corneal endothelial cell density

In the PEX group, the donor corneal ECD was 2704 ± 225 cells/mm2 at the preoperative point, and decreased to 1691 ± 498 cells/mm2 at 1 month, 1425 ± 366 cells/mm2 at 3 months, and 1281 ± 340 cells/mm2 (52.7 ± 11.7% less than the ECD of the donor graft) at 6 months after DMEK. In the FECD group, the donor corneal ECD was 2694 ± 123 cells/mm2 at the preoperative point, and decreased to 2265 ± 386 cells/mm2 at 1 month, 2120 ± 402 cells/mm2 at 3 months, and 1954 ± 464 cells/mm2 (27.5 ± 17.4% of the donor graft) at 6 months after DMEK. Although there was no significant difference between the two groups at the preoperative point (p = 0.92). However, the ECD was significantly less in the PEX group compared to the FECD group postoperatively (p = 0.032 at 1 month, p = 0.006 at 3 months, p = 0.011 at 6 months, respectively; Fig. 3).

Fig. 3
figure 3

Changes in endothelial cell density. In the pseudoexfoliation syndrome (PEX) group, the donor corneal endothelial cell density (ECD) decreases 2704 ± 225 cells/mm2 at the preoperative point to 1281 ± 340 cells/mm2 at 6 months (52.7 ± 11.7% less than the preoperative value of the donor graft). In the Fuchs endothelial corneal dystrophy (FECD) group, the donor corneal ECD decreases 2694 ± 123 cells/mm2 at the preoperative point to 1954 ± 464 cells/mm2 at 6 months (27.5 ± 17.4% less than the preoperative value of the donor graft). There is no significant difference between the two groups at the preoperative point (p = 0.92), whereas the PEX group is significantly worse than the FECD group postoperatively (p = 0.032 at 1 month, p = 0.006 at 3 months, p = 0.011 at 6 months; unpaired t-test)

Corneal endothelial characteristics

In the PEX group, coefficient of variation (CV) in cell area was 27.2 ± 7.0% at 6 months after DMEK. In the FECD group CV was 33.1 ± 2.6% at 6 months after DMEK. There was no significant difference between the two groups (p = 0.12). In the PEX group, cell hexagonality (HEX) was 46.3 ± 13.5% at 6 months after DMEK. In the FECD group HEX was 55.9 ± 9.2% at 6 months after DMEK. There was no significant difference between the two groups (p = 0.21).

Complications after DMEK

None of the eyes showed intraoperative complications, and none revealed primary graft failure. Four eyes (50%) of the FECD group required rebubbling for partial detachment. CME was present in one eye (20%) of the PEX group and one eye (12.5%) of the FECD group. In all affected eyes, the CME resolved within 6 months after the surgery with topical 0.1% (w/v) bromfenac eye drops (Bronuck; Senju Pharmaceuticals) and sub-Tenon injection of 40 mg/mL triamcinolone acetonide (Kenacort A; Bristol-Myers Squibb). None of the eyes revealed postoperative intraocular pressure elevation or exhibited glaucoma.

Discussion

The current study indicates that DMEK surgery can successfully be performed for eyes with PEX syndrome. Postoperative BSCVA and CCT were significantly improved in both the PEX and FECD groups, even though the final BSCVA was significantly worse and the final ECD was significantly less in the PEX group compared to the FECD group. To the best of our knowledge, this is the first study that focused on the outcomes of DMEK for BK due to PEX and FECD.

Reports have confirmed that the BSCVA of eyes that have undergone DMEK show rapid and sufficient improvement in the early postoperative period. Singh et al. reported that BSCVA was 0.161 ± 0.129 6 months after DMEK and 0.293 ± 0.153 6 months after DSAEK. In the present study, BSCVA 6 months after DMEK in the PEX group (0.193 ± 0.081) was comparable to previously reported results of DMEK and superior to those of DSAEK [19]. On the other hand, BSCVA in the PEX group was inferior to that of the FECD group throughout the 6-month postoperative observation period. And Singh et al. also reported that ECD loss post 6 months was 31% after DMEK. In the present study, ECD loss post 6 months after DMEK in the FECD group (27.5 ± 17.4%) was comparable to the previous results, but significantly worse in the PEX group (52.7 ± 11.7%) [19].

One of the cause is that the mean age of the PEX group was greater than that of the FECD group in the current study. The prevalence of PEX increases progressively with age, and the diagnosis of PEX has rarely been made in individuals younger than 50 [20, 21]. On the other hand, the prevalence of FECD does not significantly increase with age [22]. Subclinical dysfunction of the macula, optical nerves, and brain due to increased age may also contribute to the lower BSCVA in the PEX group. However, after we conducted age-adjusted, BSCVA and ECD loss 6 months after DMEK of the PEX group were still inferior to the FECD group.

We speculated three possible causes for the relatively deteriorated postoperative BSCVA in the PEX group: PEX material may affect the centering of the IOL, posterior segment structures, and/or cognitive function.

It has been well documented that PEX material deposits on the lens zonule cause zonular weakness and contributes to the dislocation of implanted IOLs. Ostern et al. investigated the long-term positioning of the posterior IOL following cataract surgery in eyes with and without PEX and reported that IOLs within the capsular bag were more prone to decentration in eyes with PEX [23]. The dislocated IOL could lead to more higher-order aberration, resulting in the decreased BSCVA.

PEX material has also been reported to accumulate on posterior segment structures such as the choroid and optic nerve. In eyes with PEX, choroidal thinning related to increase vascular resistance and reduce blood flow has been reported [24]. The optic disc area has also been reported as being smaller than controls, both with and without glaucoma [25].

PEX material deposits have also been reported on the cerebral meninges. Magnetic resonance imaging (MRI) of PEX patients with or without glaucoma showed a higher prevalence of white matter hyperintensities than controls [26]. Chronic cerebrovascular disease including senile dementia, cerebral atrophy and cerebral ischemia is reportedly more common in patients with PEX than patients with primary open-angle glaucoma (POAG) [27]. These changes to the posterior structures of the visual pathway may deteriorate BSCVA in patients with PEX.

As is the case with BSCVA, ECD loss post 6 months was also worse in the PEX group. The suggested causes of endotheliopathy include penetration of PEX material towards the Descemet’s membrane [28, 29] and changes in the blood-aqueous barrier [30, 31]. PEX material breaks the hexagonal connections of the endothelial layer and promotes apoptosis. The breakdown of the blood-aqueous barrier caused by PEX iridopathy may have an impact on postoperative ECD. It has been reported that preoperative cytokine levels are associated with ECD loss after DSAEK [32]. Elevated cytokine levels, including pro-inflammatory cytokines and fibrogenic growth factors in the aqueous humor in the PEX group, may facilitate the apoptosis of endothelial cells.

In conclusion, DMEK is effective for the treatment of endothelial dysfunction caused by PEX and FECD. Even though the postoperative BSCVA and ECD were slightly inferior in the eyes with PEX, DMEK provides advantages when compared with other transplant methods, such as DSAEK and penetrating keratoplasty. Future studies involving a larger number of eyes will elucidate the association between PEX and its effect on DMEK.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

BSCVA:

Best spherical corrected visual acuity

CCT:

Central corneal thickness

FECD:

Fuchs endothelial corneal dystorophy

LogMAR:

Logarithm of the minimum angle of resolution

PEX:

Pseudoexfoliation syndrome

References

  1. Melles GR, Ong TS, Ververs B, van der Wees J. Descemet membrane endothelial keratoplasty (DMEK). Cornea. 2006;25:987–90.

    Article  Google Scholar 

  2. Anshu A, Price MO, Price FW Jr. Risk of corneal transplant rejection significantly reduced with Descemet's membrane endothelial keratoplasty. Ophthalmology 2012;119:536–540.

    Article  Google Scholar 

  3. Kruse FE, Schrehardt US, Tourtas T. Optimizing outcomes with Descemet’s membrane endothelial keratoplasty. Curr Opin Ophthalmol. 2014;25:325–34.

    Article  Google Scholar 

  4. Li S, Liu L, Wang W, Huang T, Zhong X, Yuan J, et al. Efficacy and safety of Descemet's membrane endothelial keratoplasty versus Descemet's stripping endothelial keratoplasty: a systematic review and meta-analysis. PLoS One. 2017;12:e0182275.

    Article  Google Scholar 

  5. Hayashi T, Oyakawa I, Kato N. Techniques for learning Descemet membrane endothelial keratoplasty for eyes of Asian patients with shallow anterior chamber. Cornea. 2017;36:390–3.

    PubMed  PubMed Central  Google Scholar 

  6. Nazarali S, Damji F, Damji KF. What have we learned about exfoliation syndrome since its discovery by John Lindberg 100 years ago? Br J Ophthalmol. 2018. https://doi.org/10.1136/bjophthalmol-2017-311321.

    Article  Google Scholar 

  7. Lindberg JG. Clinical investigations on depigmentation of the pupillary border and translucency of the iris in cases of senile cataract and in normal eyes in elderly persons. Acta Ophthalmol Suppl. 1989;190:1–96.

    CAS  PubMed  Google Scholar 

  8. Asano N, Schlötzer-Schrehardt U, Naumann GO. A histopathologic study of iris changes in pseudoexfoliation syndrome. Ophthalmology. 1995;102:1279–90.

    Article  CAS  Google Scholar 

  9. Wenkel M, Schlötzer-Schrehardt U. The composition of exfoliation material and the cells involved in its production. J Glaucoma. 2014;23:S12–4.

    Article  Google Scholar 

  10. Streeten BW, Li ZY, Wallace RN, Eagle RC Jr, Keshgegian AA. Pseudoexfoliative fibrillopathy in visceral organs of a patient with pseudoexfoliation syndrome. Arch Ophthalmol. 1992;110:1757–62.

    Article  CAS  Google Scholar 

  11. Schlötzer-Schrehardt UM, Koca MR, Naumann GO, Volkholz H. Pseudoexfoliation syndrome: ocular manifestation of a systemic disorder? Arch Ophthalmol. 1992;110:1752–6.

    Article  Google Scholar 

  12. Ritch R. Exfoliation syndrome-the most common identifiable cause of open-angle glaucoma. J Glaucoma. 1994;3:176–7.

    CAS  PubMed  Google Scholar 

  13. Zheng X, Inoue Y, Shiraishi A, Hara Y, Goto T, Ohashi Y. In vivo confocal microscopic and histological findings of unknown bullous keratopathy probably associated with pseudoexfoliation syndrome. BMC Ophthalmol. 2012;12:1471–6.

    Article  Google Scholar 

  14. Zheng X. New findings for an old disease: morphological studies on pseudoexfoliation syndrome-related keratopathy and binocular asymmetry. Cornea. 2013;32:S84–90.

    Article  Google Scholar 

  15. Zheng X, Shiraishi A, Okuma S, Mizoue S, Goto T, Kawasaki S, et al. In vivo confocal microscopic evidence of keratopathy in patients with pseudoexfoliation syndrome. Invest Ophthalmol Vis Sci. 2011;52:1755–61.

    Article  Google Scholar 

  16. Matsuzawa A, Hayashi T, Oyakawa I, Yuda K, Shimizu T, Mizuki N, et al. Use of four asymmetric marks to orient the donor graft during Descemet’s membrane endothelial keratoplasty. BMJ Open Ophthalmol. 2017;1:e000080.

    Article  Google Scholar 

  17. Hayashi T, Yuda K, Oyakawa I, Kato N. Use of brilliant blue G in Descemet's membrane endothelial keratoplasty. Biomed Res Int. 2017;2017:9720389.

    Article  Google Scholar 

  18. Dapena I, Moutsouris K, Droutsas K, Ham L, van Dijk K, Melles GR. Standardized “no-touch” technique for Descemet membrane endothelial keratoplasty. Arch Ophthalmol. 2011;129:88–94.

    Article  Google Scholar 

  19. Singh A, Zarei-Ghanavati M, Avadhanam V, Liu C. Systematic review and meta-analysis of clinical outcomes of Descemet membrane endothelial keratoplasty versus Descemet stripping endothelial keratoplasty/Descemet stripping automated endothelial keratoplasty. Cornea. 2017;36:1437–43.

    Article  Google Scholar 

  20. You QS, Xu L, Wang YX, Yang H, Ma K, Li JJ, Zhang L, Jonas JB. Pseudoexfoliation: normative data and. Associations: the Beijing eye study 2011. Ophthalmology. 2013;120:1551–8.

    Article  Google Scholar 

  21. Arnarsson A, Damji KF, Sverrisson T, Sasaki H, Jonasson F. Pseudoexfoliation in the Reykjavik eye study: prevalence and related ophthalmological variables. Acta Ophthalmol Scand. 2007;85:822–7.

    Article  Google Scholar 

  22. Eghrari AO, McGlumphy EJ, Iliff BW, Wang J, Emmert D, Riazuddin SA, et al. Prevalence and severity of fuchs corneal dystrophy in Tangier Island. Am J Ophthalmol. 2012;153:1067–72.

    Article  Google Scholar 

  23. Ostern AE, Sandvik GF, Drolsum L. Positioning of the posterior intraocular lens in the longer term following cataract surgery in eyes with and without pseudoexfoliation syndrome. Acta Ophthalmol. 2014;92:253–8.

    Article  Google Scholar 

  24. Goktas S, Sakarya Y, Ozcimen M, Sakarya R, Bukus A, Ivacik IS, et al. Choroidal thinning in pseudoexfoliation syndrome detected by enhanced depth imaging optical coherence tomography. Eur J Ophthalmol. 2014;24:879–84.

    Article  Google Scholar 

  25. Jonas JB, Papastathopoulos KI. Optic disk appearance in pseudoexfoliation syndrome. Am J Ophthalmol. 1997;123:174–80.

    Article  CAS  Google Scholar 

  26. Yüksel N, Anik Y, Altintaş O, Onur I, Cağlar Y, Demirci A. Magnetic resonance imaging of the brain in patients with pseudoexfoliation syndrome and glaucoma. Ophthalmologica. 2006;220:125–30.

    Article  Google Scholar 

  27. Ritland JS, Egge K, Lydersen S, Juul R, Semb SO. Exfoliative glaucoma and primary open-angle glaucoma: associations with death causes and comorbidity. Acta Ophthalmol Scand. 2004;82:401–4.

    Article  CAS  Google Scholar 

  28. Schlötzer-Schrehardt UM, Dörfler S, Naumann GO. Corneal endothelial. Involvement in pseudoexfoliation syndrome. Arch Ophthalmol. 1993;111:666–74.

    Article  Google Scholar 

  29. Naumann GO, Schlötzer-Schrehardt U. Keratopathy in pseudoexfoliation syndrome as a cause of corneal endothelial decompensation: a clinicopathologic study. Ophthalmology. 2000;107:1111–24.

    Article  CAS  Google Scholar 

  30. Küchle M, Vinores SA, Mahlow J, Green WR. Blood-aqueous barrier in pseudoexfoliation syndrome: evaluation by immunohistochemical staining of endogenous albumin. Graefes Arch Clin Exp Ophthalmol. 1996;234:12–8.

    Article  Google Scholar 

  31. Yagi-Yaguchi Y, Yamaguchi T, Higa K, Suzuki T, Aketa N, Dogru M, et al. Association between corneal endothelial cell densities and elevated cytokine levels in the aqueous humor. Sci Rep. 2017;7:13603.

    Article  Google Scholar 

  32. Yazu H, Yamaguchi T, Aketa N, Higa K, Suzuki T, Yagi-Yaguchi Y, et al. Preoperative aqueous cytokine levels are associated with endothelial cell loss after Descemet’s stripping automated endothelial keratoplasty. Invest Ophthalmol Vis Sci. 2018;59:612–20.

    Article  CAS  Google Scholar 

Download references

Acknowledgments

None.

Funding

Nothing.

Author information

Authors and Affiliations

Authors

Contributions

TH, and NK suggested the study and performed the surgeries. SK and TS were major contributors in writing the manuscript. HT analyzed the data. NM, and KN organized the study. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Takahiko Hayashi.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the Institutional Review Board of Yokohama Minami Kyosai Hospital, Japan under the reference number (YKH_30_02_08). Informed consent was obtained in written style for each surgery. We carefully followed all ethical principles within the Declaration of Helsinki.

Consent for publication

Not applicable

Competing interests

All the authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional file

Additional file 1:

Figure S1. Before Descemet’s membrane endothelial keratoplasty (DMEK) (A) and after DMEK (B) in the PEX group. Corneal transparency remarkably improves after phacoemulsification and DMEK. Despite impressive improvement of the corneal edema, the PEX materials are clearly detectable on the iris before and after DMEK (Arrows). (PDF 150 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tase, S., Shimizu, T., Hayashi, T. et al. Descemet’s membrane endothelial keratoplasty for pseudoexfoliation syndrome: a case series. BMC Ophthalmol 19, 119 (2019). https://doi.org/10.1186/s12886-019-1130-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-019-1130-1

Keywords