Classification of optical coherence tomography images using a capsule network

Abstract

Background

Classification of optical coherence tomography (OCT) images can be achieved with high accuracy using classical convolution neural networks (CNN), a commonly used deep learning network for computer-aided diagnosis. Classical CNN has often been criticized for suppressing positional relations in a pooling layer. Therefore, because capsule networks can learn positional information from images, we attempted application of a capsule network to OCT images to overcome that shortcoming. This study is our attempt to improve classification accuracy by replacing CNN with a capsule network.

Methods

From an OCT dataset, we produced a training dataset of 83,484 images and a test dataset of 1000 images. For training, the dataset comprises 37,205 images with choroidal neovascularization (CNV), 11,348 with diabetic macular edema (DME), 8616 with drusen, and 26,315 normal images. The test dataset has 250 images from each category. The proposed model was constructed based on a capsule network for improving classification accuracy. It was trained using the training dataset. Subsequently, the test dataset was used to evaluate the trained model.

Results

Classification of OCT images using our method achieved accuracy of 99.6%, which is 3.2 percentage points higher than that of other methods described in the literature.

Conclusion

The proposed method achieved classification accuracy results equivalent to those reported for other methods for CNV, DME, drusen, and normal images.

Peer Review reports

Background

The increase of diabetic patients has come to present difficulty worldwide in recent years. Globally, an estimated 422 million adults were living with diabetes mellitus in 2014, compared to 108 million in 1980 [1]. Diabetes causes diabetic nephropathy, diabetic neuropathy, and diabetic macular edema (DME). In fact, DME might affect up to 746,000 persons with diabetes who are 40 years or older in the United States [2]. Although DME engenders vision loss, early detection and prompt treatment can avert that outcome. From a much broader perspective, age-related macular degeneration (AMD) is expected to affect 8.7% of the worldwide population. The projected number of people with the disease is around 196 million in 2020, increasing to 288 million in 2040 [3]. Early detection and prompt treatment can prevent AMD leading to vision loss. To detect these diseases, optical coherence tomography (OCT) is the most commonly used imaging modality in ophthalmology [4]. These initial diseases can be detected by screening with OCT, but increased screening with OCT images multiplies the burdens on ophthalmologists, who must interpret these images. Therefore, an automatic diagnostic screening system has been developed actively to reduce ophthalmologists’ burdens.

In the field of medical image classification with deep learning [5,6,7,8,9,10], OCT image classification has been undertaken in earnest. Kermany et al. used Inception-V3 for the classification of OCT images into four classes: choroidal neovascularization (CNV), DME, drusen, and normal. The classification accuracy was reportedly 96.1% [11]. However, traditional convolutional neural networks (CNNs) have sometimes been criticized because their pooling operations nearly eliminate positional information [12]. Losing positional information might be a bottleneck hindering efforts to improve OCT image classification accuracy.

To overcome this shortcoming, Hinton et al. developed a capsule network that can learn positional relations among images using capsules [13,14,15]. Capsule networks can achieve better performance than existing CNN. For this study using an OCT dataset used for earlier research, we attempted to achieve higher classification accuracy using a model based on a capsule network.

Methods

OCT dataset

Kermany et al. released the OCT dataset used for an earlier study to Kaggle [11]. That dataset, which included retinal OCT images, was downloaded from the Kaggle website (https://www.kaggle.com/paultimothymooney/kermany2018, accessed on May 10, 2018). This published dataset includes 84,484 images: 83,484 from the training dataset and 1000 from a test dataset. The dataset included fewer OCT images than the dataset used for the earlier study. The training dataset comprised 37,205 images showing CNV, 11,348 showing DME, 8616 showing drusen, and 26,315 normal images. The test dataset comprised 250 images from each class.

We divided the training dataset into a sub-training dataset and a validation dataset, which included 4000 images extracted randomly from 1000 images of each class. The sub-training dataset includes the remaining training data. The image format for the OCT dataset is Joint Photographic Experts Group 8-bit. Figure 1 portrays some OCT dataset images. Figure 2 presents OCT dataset division details.

Fig. 1
figure 1

Optical coherence tomography images in the OCT dataset. Panels present images: far left, choroidal neovascularization (CNV); middle left, diabetic macular edema (DME); middle right, drusen; far right, normal

Fig. 2
figure 2

Details of OCT dataset division. The OCT dataset comprises training and test datasets. The training dataset was divided into a sub-training dataset and a validation dataset

Capsule network

Capsules, which are groups of neurons with outputs representing different properties of the same object, have a vector that can learn positional relations between features in images [15]. The coupling coefficients between capsules and all capsules in the layer above it learn with dynamic routing, which enables them to learn positional relations among features. Reportedly, the method provides higher generalization performance than that provided by traditional CNN for small affine transformations of the training data. For that reason, the network requires far fewer training data [13,14,15].

Model architecture

Capsule network architecture

The original capsule network was a network for classification of MNIST [16] images with 28 × 28 size. The network architecture was shallow, with only two convolutional layers and one fully connected layer. The first layer had 256 filters, 9 × 9 convolution kernels with a stride of 1. The second layer (Primary Caps) was a convolutional capsule layer with 32 channels of convolutional eight dimension (8D) capsules (i.e., each primary capsule contains eight convolutional units with a 9 × 9 kernel and a stride of 2 pixels). Both activation functions were rectified linear units. The final layer (Digit Caps) had one 16D capsule per digit class. Each capsule received input from all capsules of the layer below.

The likelihood vector, elements of which were the likelihood of each digit class, was calculated from the L2 norm of Digit Caps. The output label was the class of the highest component in the likelihood vector [15]. Details of this network architecture are presented in Fig. 3a.

Fig. 3
figure 3

Network architecture details. a Capsule network architecture and b proposed network architecture

Proposed network architecture

For classification of images of 512 × 512, we propose a network model with four added convolutional layers to the capsule network. The first reason is that increasing the convolutional layers of the capsule network was expected to improve accuracy [17]. The second reason is that input images were convolved as the same size as Primary Caps in the capsule network. Figure 4 presents the proposed network architecture. Figure 3b shows some related details.

Fig. 4
figure 4

Proposed network architecture. The proposed model has six convolution layers (five convolution layers + primary caps) and OCT Caps. The activity vector length of each capsule in the OCT Caps layer shows the presence of an instance of each class. It is used to calculate the classification loss

The first layer has 256 filters: 4 × 4 convolution kernels with a stride of 2 pixels. The second layer has 128 filters. The third and the fourth layers have, respectively, 64 layers. The fifth layer has 128 layers. The sixth layer (Primary Caps) has 32 × 8 filters, 5 × 5 convolutional kernels with a stride of 2 pixels to produce 32 capsule maps with capsules of 8D. This layer constructs capsules for dynamic routing operations in the next layer. The OCT Caps has one 16D capsule per class. Each capsule receives input from all capsules of the layer below. The likelihood vector is calculated from OCT Caps by L2 norm. The highest elements in the likelihood vector are defined as the output label. All activation functions are leaky rectified linear unit (leaky ReLU) functions for which the configurable slope value is 0.05 instead of a rectified linear unit (ReLU) function.

At the Intelligent Systems Research Institute, we built the proposed network model on Reedbush-L running on a computer (Xeon CPUs; Intel Corp. and Tesla P100 16 GB GPU; NVIDIA Corp.) with a Chainer (ver. 3.3.0) deep learning framework.

Preprocessing and data augmentation

The proposed network model requires a 512 × 512 image. However, the dataset images were 384–1536 pixels wide and 496–512 pixels high. Therefore, the images were resized in terms of width and height to 512 pixels using linear interpolation. In addition, the OCT images were shifted by up to 16 pixels in each direction with zero padding to increase the number of learning data. As a result, the number of images used for learning was increased to 65,536 times (16 × 16 × 16 × 16).

Learning

The OCT dataset published in Kaggle consists of a training dataset and a test dataset. We trained the proposed model using an early stopping algorithm [18]. Therefore, we divided the training dataset into a validation dataset and sub-training dataset after observing the generalization performance of the proposed model in learning. The validation dataset comprises 4000 images from 1000 images extracted randomly from each class. The sub-training dataset consists of the remaining training dataset. The test dataset had 250 images for each class. The training dataset, the sub-training dataset, the validation dataset, and the test dataset were designated respectively as Xtrain, Xsubtrain, Xvalid, and Ytest.

The model was trained with Xsubtrain and Xvalid using Adam optimizer [19]. The batch size was set to 128. The model was trained for 50 epochs. Early stopping occurred when the Xvalid accuracy became the best in learning. This learning curve is depicted in Fig. 5. Then, the proposed model was evaluated using the test dataset.

Fig. 5
figure 5

Learning curve. Early stopping occurred when the validation dataset accuracy was the best in learning

Additionally, we trained Inception-v3 under the same learning conditions to compare the proposed model and those of earlier research. Then, Inception-V3, which was trained, was evaluated using the test dataset.

Visualizing feature maps

We visualized feature maps using a method inspired by class activation mapping (CAM) [20] to elucidate which parts in the OCT image were strongly influential. An image was input to the trained model. Then 256 feature maps (6 × 6) were generated from Convolution layer 6. After the averaged feature map (6 × 6) was resized to input size (512 × 512), it was superimposed on the input image as a heat map image.

Results

We evaluated the proposed model using the Ytest test dataset. The numbers of correct answers and rates of CNV, DME, drusen, and normal were, respectively, 250 (100%), 248 (99.2%), 248 (99.2%), and 250 (100%). The model achieved average classification accuracy of 99.6%. More detailed results are presented as a confusion matrix in Fig. 6a.

Fig. 6
figure 6

Confusion matrixes of learned model classification. a Confusion matrix by the proposed model and b used by Inception-V3

We evaluated Inception-V3 similarly. The accuracy of Inception-V3 is presente in Fig. 6b as a confusion matrix. The numbers of correct answers and rates of CNV, DME, drusen, and normal were, respectively, 249 (99.6%), 250 (100%), 249 (99.6%), and 250 (100%). Consequently, the average accuracy achieved using Inception-V3 was 99.8%.

We visualized likelihood vectors, for which coefficients denote the probability of each class, as calculated from the OCT Caps. Components of likelihood vectors are presented in Fig. 7, the axes of which respectively show the likelihoods of CNV, DME, and DRUSEN. The marker colors correspond to the correct labels of four classes in the test dataset. Also, CNV, DME, DRUSEN, and NORMAL are presented respectively as blue, red, green, and yellow plotted values.

Fig. 7
figure 7

Visualizing of likelihood vectors in the four classes. Likelihood vectors calculated from the test dataset are shown. Axes show the likelihood of diseases of three kinds. Blue, red, green, and yellow lines respectively represent true labels of CNV, DME, DRUSEN, and NORMAL

Heat map images for the respective classes are portrayed in Fig. 8. The red zones in heat map images show activated parts of the proposed model. After expert ophthalmologists assessed the heat map images, they confirmed that the activated parts corresponded to the observed location in the interpretation of OCT image. Therefore, it can be said, at least qualitatively, that the proposed model was trained accurately. Additionally, heat map portrayals of images that were misclassified by the proposed model are presented in Fig. 9.

Fig. 8
figure 8

Visualization of feature maps as heat maps. Left images are input images. Right images are feature maps superimposed on an input image. Top to bottom, panels show CNV, DME, DRUSEN, and NORMAL

Fig. 9
figure 9

Visualization of feature maps misclassified by the proposed model. The proposed model misclassified DME (a and b) and DRUSEN (c and d) as CNV

Discussion

For the classification of four classes of OCT images, the proposed method achieved high accuracy of 99.6% using the network model based on a capsule network. By contrast, the best accuracy obtained in earlier studies was 96.1%, obtained when using Inception-v3. This model has a pooling layer, which is a primary feature of CNN. In addition, the accuracy of Inception-V3 in the same condition was 99.8%. Therefore, the proposed model, which is much shallower than Inception-V3, compares favorably with it in terms of classification accuracy.

According to an earlier study [21], six ophthalmologists diagnosed the same test dataset and achieved classification accuracies of 92.1–99.7%, with mean accuracy of 96.7%. That finding suggests that the proposed network model performance in terms of OCT image classification was equivalent to those of expert ophthalmologists.

Misclassified heat map images suggest that the activated parts in those images are the same locations that ophthalmologists interpret. Therefore, the proposed model did not specifically examine wrong parts. One can infer that those misclassified images include some disease.

In a typical clinical case, a fundus image is taken using fluorescein angiography in addition to OCT images. Fluorescein angiography nevertheless presents several important shortcomings. The first is a contraindication to perform fluorescein angiography for patients with severe cardiac disease, severe cerebrovascular disease, severe diabetes, and liver cirrhosis [22,23,24]. Moreover, it is impossible to obtain contrast agents for pregnant women [25, 26]. The second shortcoming is the risk of side effects presented by fluorescein angiography, such as anaphylaxis (difficulty of breathing and loss of consciousness) and cardiac arrest [24, 27, 28]. For this study, the proposed model enables the classification of CNV, DME, drusen, and normal with high accuracy using OCT images alone. Therefore, the proposed model can reduce burdens imposed on ophthalmologists and patients.

An important limitation of this study is that the proposed model classifies images of only four types: CNV, DME, drusen, and normal. Retinal disease, such as glaucoma, Branchi Retinal Vein Occlusion cannot be predicted because these diseases were not trained in this study. Future studies will be conducted to classify those images using this method.

Conclusions

This network model with four convolution layers of an added capsule network achieved high accuracy for the released OCT dataset. Results obtained for the four classifications compare favorably with those reported from earlier research. This system can reduce ophthalmologists’ burdens and can be expected to improve patient access to rapid treatment.

Availability of data and materials

All data analyzed during this study are available from Daniel Kermany, Kang Zhang, and Michael Goldbaum (2018), “Labeled Optical Coherence Tomography (OCT) and Chest X-Ray Images for Classification”, Mendeley Data v2 (https://doi.org/10.17632/rscbjbr9sj.2). Data generated from analyses described in the Results section are deposited from the corresponding author upon request.

Abbreviations

CNN:

Convolutional neural network

OCT:

Optical coherence tomography

CNV:

Choroidal neovascularization

DME:

Diabetic macular edema

AMD:

Age-related macular degeneration

ReLU:

Rectified linear unit

CAM:

Class activation mapping

References

  1. Chan M. Global report on diabetes. World Health Organ. 2014;58:1–88. https://doi.org/10.1128/AAC.03728-14.

    Article  CAS  Google Scholar 

  2. Varma R, Bressler NM, Doan QV, Gleeson M, Danese M, Bower JK, et al. Prevalence of and risk factors for diabetic macular edema in the United States. JAMA Ophthalmol. 2014;132:1334. https://doi.org/10.1001/jamaophthalmol.2014.2854.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Wong WL, Su X, Li X, Cheung CMG, Klein R, Cheng C, et al. Global prevalence of age-related macular degeneration and disease burden projection for 2020 and 2040: a systematic review and meta-analysis. Lancet Glob Heal. 2014;2:e106–16. https://doi.org/10.1016/S2214-109X(13)70145-1.

    Article  Google Scholar 

  4. Swanson EA, Fujimoto JG. The ecosystem that powered the translation of OCT from fundamental research to clinical and commercial impact [invited]. Biomed Opt Express. 2017;8:1638. https://doi.org/10.1364/BOE.8.001638.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Singh R, Kalra MK, Nitiwarangkul C, Patti JA, Homayounieh F, Padole A, et al. Deep learning in chest radiography: detection of findings and presence of change. PLoS One. 2018;13:1–12.

    CAS  Google Scholar 

  6. Shi W, Grainger AT, Tustison NJ, Qing K, Roy R, Berr SS. Deep learning-based quantification of abdominal fat on magnetic resonance images. PLoS One. 2018;13:1–16.

    CAS  Google Scholar 

  7. Cui J, Liu X, Wang Y, Liu H. Deep reconstruction model for dynamic PET images. PLoS One. 2017;12:1–21.

    Google Scholar 

  8. Zech JR, Badgeley MA, Liu M, Costa AB, Titano JJ, Oermann EK. Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: a cross-sectional study. PLoS Med. 2018;15:1–17.

    Article  Google Scholar 

  9. Khojasteh P, Aliahmad B, Kumar DK. Fundus images analysis using deep features for detection of exudates, hemorrhages and microaneurysms. BMC Ophthalmol. 2018;18:288. https://doi.org/10.1186/s12886-018-0954-4.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Ahn JM, Kim S, Ahn K-S, Cho S-H, Kim US. Accuracy of machine learning for differentiation between optic neuropathies and pseudopapilledema. BMC Ophthalmol. 2019;19:178. https://doi.org/10.1186/s12886-019-1184-0.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Kermany DS, Goldbaum M, Cai W, Lewis MA. Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning Resource Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning. Cell. 2018;172:1122–31.e9. https://doi.org/10.1016/j.cell.2018.02.010.

    Article  CAS  PubMed  Google Scholar 

  12. Phaye SSR, Sikka A, Dhall A, Bathula D. Dense and Diverse Capsule Networks: Making the Capsules Learn Better; 2018. p. 1–11. http://arxiv.org/abs/1805.04001.

    Google Scholar 

  13. Hinton GE, Krizhevsky A, Wang SD. Transforming Auto-Encoders; 2011. p. 44–51. https://doi.org/10.1007/978-3-642-21735-7_6.

    Book  Google Scholar 

  14. Sabour S, Frosst N, Hinton GE. Matrix Capsules With EM Routing. 39th AIAA/ASME/SAE/ASEE Jet Propuls Conf Exhib; 2017. p. 1–15. https://doi.org/10.2514/6.2003-4412.

    Book  Google Scholar 

  15. Sabour S, Frosst N, Hinton GE: Dynamic Routing Between Capsules. 2017; Nips http://arxiv.org/abs/1710.09829.

    Google Scholar 

  16. LeCun Y, Cortes C, Burges C. The MNIST DATABASE of handwritten digits. The Courant Institute of Mathematical Sciences; 1998.

    Google Scholar 

  17. Xi E, Bing S, Jin Y. Capsule Network Performance on Complex Data, 10707 Fall; 2017. p. 1–7. http://arxiv.org/abs/1712.03480.

    Google Scholar 

  18. Goodfellow I, Bengio Y, Courville A. Deep learning. Cambridge: MIT Press; 2016. http://www.deeplearningbook.org.

  19. Kingma DP, Ba JA. A Method for Stochastic Optimization, vol. 94; 2014. p. 172–9. arXiv:1412.6980v9.

    Google Scholar 

  20. Zhou B, Khosla A, Lapedriza A, Oliva A, Torralba A. Learning Deep Features for Discriminative Localization. In: 2016 IEEE Conf Comput Vis Pattern Recognit; 2015. p. 2921–9. https://doi.org/10.1109/CVPR.2016.319.

    Chapter  Google Scholar 

  21. Szegedy C, Vanhoucke V, Ioffe S, Shlens J, Wojna Z. Rethinking the Inception Architecture for Computer Vision. In: 2016 IEEE conference on computer vision and pattern recognition (CVPR). IEEE; 2016. p. 2818–26. https://doi.org/10.1109/CVPR.2016.308.

    Chapter  Google Scholar 

  22. Lira RPC, de A OCL, MVRB M, Silva AR, de C P. Adverse reactions of fluorescein angiography: A prospective study. Arq Bras Oftalmol. 2007;70:615–8.

    Article  Google Scholar 

  23. Lempert P. Cardiac arrest following fluorescein angiography. JAMA J Am Med Assoc. 1980;244:660.

    Article  CAS  Google Scholar 

  24. Kornblau IS, El-Annan JF. Adverse reactions to fluorescein angiography: a comprehensive review of the literature. Surv Ophthalmol. 2019;64:679–6793. https://doi.org/10.1016/j.survophthal.2019.02.004.

    Article  PubMed  Google Scholar 

  25. Musa F, Muen WJ, Hancock R, Clark D. Adverse effects of fluorescein angiography in hypertensive and elderly patients. Acta Ophthalmol Scand. 2006;84:740–2.

    Article  Google Scholar 

  26. Beleña JM, Núñez M, Rodríguez M. Adverse reactions due to fluorescein during retinal angiography. JSM Ophtalmol. 2013;1:4–7.

    Google Scholar 

  27. Bearelly S, Rao S, Fekrat S. Anaphylaxis following intravenous fluorescein angiography in a vitreoretinal clinic: report of 4 cases. Can J Ophthalmol. 2009;44:444–5. https://doi.org/10.3129/i09-068.

    Article  PubMed  Google Scholar 

  28. Lim LS, Mitchell P, Seddon JM, Holz FG, Wong TY. Age-related macular degeneration. Lancet. 2012;379:1728–38. https://doi.org/10.1016/S0140-6736(12)60282-7.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

None.

Funding

This work was partly supported by a Japan Society for the Promotion of Science (JSPS) KAKENHI Grant (No. 18 K07646). The funders had no role in study design, data collection and analysis, decision to publish, or manuscript preparation.

Author information

Authors and Affiliations

Authors

Contributions

All authors participated in designing this study. TT, YH, KF and TH analyzed the data. TT, AO, YS and JK were major contributors to the writing of the manuscript. TM, AM, KS, TK and JK participated in the editing and review of the manuscript. JK supervised the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Jun’ichi Kotoku.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tsuji, T., Hirose, Y., Fujimori, K. et al. Classification of optical coherence tomography images using a capsule network. BMC Ophthalmol 20, 114 (2020). https://doi.org/10.1186/s12886-020-01382-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-020-01382-4

Keywords