Clinical observation of phacoemulsification under the low perfusion pattern and low negative pressure in patients with low corneal endothelial cell density

Abstract

Background

To observe the safety and effect of phacoemulsification combined with intraocular lens (IOL) implantation in patients with low corneal endothelial cell density (CD) under the low perfusion pattern with low negative pressure.

Methods

In this retrospective case series study, a total of 16 patients (17 eyes) were studied. They had all been diagnosed with low corneal endothelial (CD) and cataracts in the First Affiliated Hospital of Fujian Medical University from December 2019 to October 2021. They underwent phacoemulsification combined with IOL implantation under the low perfusion pattern with low negative pressure. The variations of corneal endothelial( CD), coefficient of variation (CV) of the cell area, central corneal thickness (CCT), visual acuity, and intraocular pressure before and after the operation were observed and assessed. Then a paired t-test, repeated measures analysis of variance, and Pearson correlation analysis were adopted for data analysis.

Results

The mean intraocular pressure of the 17 eyes was 16.88 ± 6.47 mmHg before the operation and 14.41 ± 3.10 mmHg after the operation, showing a statistically significant difference of t = 2.222, and p = 0.041. Before the operation, the mean visual acuity was 0.16 ± 0.09, and after the operation, it was 0.45 ± 0.16, displaying a statistically significant difference of t = -9.917, p < 0.001. Before and after the operation, four of the 17 eyes had no detectable CD. The mean CD of the other 13 eyes at one month after the operation (644.308 ± 106.24 cells/mm2) was lower than that before the operation (709.62 ± 119.19 cells/mm2), and the differences were statistically significant (F = 20.044, p < 0.001). However, no statistically significant differences were found in the mean CV before the operation (31.23 ± 4.21), and at one month after the operation (32.62 ± 3.80; F = 2.130, p = 0.157). Moreover, the mean CCT of 14 eyes at one month after the operation (562.72 ± 27.82 μm) was larger than that before the operation (534.79 ± 24.69 μm).

Conclusions

The low perfusion pattern with low negative pressure is safe and effective for corneal endothelial dysfunction patients complicated with cataracts.

Peer Review reports

Background

Cataracts can mainly be treated by extraction combined with intraocular lens (IOL) implantation. At present, phacoemulsification, as a cataracts extraction method, has been widely applied in clinics because it causes small wounds and a low postoperative astigmatism rate, with faster visual acuity rehabilitation [1]. However, the ultrasound energy, the sheer force generated by the vortex of perfusion fluid of the anterior chamber, and the floating lens debris in the anterior chamber will damage corneal endothelial cells to some extent, which will reduce the corneal endothelial cell density (CD). Hence, cataracts extraction combined with IOL implantation is not particularly safe for some patients with corneal endothelial injury [2]. There are 1400–2500/mm2 corneal endothelial cells in normal adults. Clinically, some patients with low corneal endothelial CD combined with cataracts are often intractable cases. Therefore, the way to protect the corneal endothelium during the operation is still a focus of cataracts surgeons [3]. In the present study, the clinical effect of cataracts extraction in 17 eyes with corneal endothelial CD < 1,000/mm2 complicated by cataracts was retrospectively assessed, and the application effectiveness of the low perfusion pattern with low negative pressure in such patients was explored.

Methods

Research subjects

This study protocol adhered to the principle stated in the Declaration of Helsinki and was approved by the Ethics Committee of the First Affiliated Hospital of Fujian Medical University. A total of 16 patients (17 eyes) with a preoperative corneal endothelial CD less than 1000/mm2 (554/mm2–996/mm2) who received phacoemulsification combined with IOL implantation in the First Affiliated Hospital of Fujian Medical University from December 2019 to October 2021 were selected. Based on the Emery nuclear grading system, the lens nuclei of all eyes were classified into grades III–IV before the operation. There were 12 eyes with grade III nuclei and 5 with grade IV nuclei. Exclusion criteria were set as follows: (1) patients with definite retinal or optic nerve diseases or other eye diseases, (2) those who have had other operations performed or have suffered from external injuries in the operated eyes, (3) those with secondary glaucoma or severe uveitis after the operation, and (4) those with preoperative corneal edema.

Operation methods

One ophthalmologist carried out all operations. There were 17 eyes with grades III–IV nuclei. A Stellaris phacoemulsification machine (Bausch + Lomb, USA) was employed for cataract phacoemulsification under the continuous ultrasound energy release mode. During the phacoemulsification, an appropriate amount of 3% sodium hyaluronate was first injected into the anterior chamber to form the anterior chamber operating space using the “soft-shell technique” until the injection fluid was uniformly attached to the corneal endothelial surface. The phacoemulsification was performed under the low perfusion pattern (height of perfusion bottles of 95 cm) with low negative pressure (< 250 mmHg), The energy output of the ultrasonic device is characterized by three modes: continuous, pulse, and burst. In this study, we opted for the burst mode, with the maximum energy set at 60%, the maximum vacuum pressure ranging from 250 to 300 mm Hg, and a flow rate of 40ml/min. The single burst blockage duration was configured at 50ms, with the foot pedal employed for linear control of the number of burst blockages. Beginning at the third gear, a burst occurred every 2.5s, while continuous burst blockages were executed at the lowest point of the third gear.

Next, the lens nucleus was removed through phacoemulsification using the soft-shell technique, while residual cortex was removed through automated irrigation and aspiration. Subsequently, 3% sodium hyaluronate was injected into the anterior chamber again to support the capsular bag, Utilizing the protection afforded by the soft-shell technique on the endothelium, we processed the nuclear fragments using the split-flip method. The ultrasonic probe, which utilizes linear ultrasonic energy, was inserted directly into the center of the lens nucleus, thereby securing it. An auxiliary incision was used to insert the splitter into the equator of the lens nucleus. Relative movement of the splitter and the ultrasonic probe led to misplacement at the point of contact, thereby splitting the lens nucleus into two halves. The lens nucleus was then rotated 90° and progressively cut into smaller pieces using the same methodology. These nuclear fragments were aspirated using vacuum suction and subsequently flipped out from within the lens capsule. an IOL was implanted, and the viscoelastic agent was removed to form a watertight anterior chamber.

Clinical outcome measurements

Routine visual acuity and intraocular pressure (IOP) were conducted a non-contact tonometer and slit lamp examination were performed before and after the operation at 1 day and 1month respectively. The central corneal thickness (CCT), corneal endothelial CD, and coefficient of variation (CV) of the cell area were measured using specular microscope (TOPCON, Japan) by a trained ophthalmologic physician. The loss rate of endothelial cells was calculated as follows: corneal endothelial cell loss rate = (preoperative CD-postoperative CD)/preoperative CD×100%.

Statistical methods

This was a retrospective case series study. SPSS 21.0 was adopted for statistical analysis. Data were shown as mean ± SD (x̅±s). Paired t-test was used to investigate the differences in the IOP and visual acuity before and after the operation. The differences in CV, CD and CCT were analyzed using repeated measures analysis of variance (RM ANOVA). In addition, a Pearson correlation analysis was conducted to analyze the correlations of each factor with the corneal endothelial cell loss rate and postoperative CCT. p < 0.05 represented that the difference was statistically significant.

Results

Demographic and ocular characteristics of patients

Seventeen eyes of 16 cataract patients with low endothelial CD underwent phacoemulsification and IOL implantation, including 7 eyes of 7 males and 10 eyes of 9 females. The average age of the patients was 68.9 ± 5.25 years. The causes of poor corneal endothelial CD in these patients including glaucoma, keratitis, Fuchs endothelial dystrophy, iridoschisis and some unknown reasons. The average energy of superemulsion is 11 ± 4%. The average time of superemulsion is 27 ± 11 s, the cumulative energy is 325 ± 215%.Among the 17 eyes, corneal endothelial CD could not be measured in four eyes. Meanwhile, three eyes of them had no detectable CCT. Thus, corneal endothelial CD and CV of 13 eyes and CCT of 14 eyes were analyzed in this study (Tables 1 and 2).

Table 1 Preoperative information of patients
Table 2 The postoperative outcomes of patients after one day (1D) and one month (1 M)

Comparisons of visual acuity and IOP before and after the operation

As shown in Table 3, the mean IOP was 16.88 ± 6.47 mmHg and 14.41 ± 3.10 mmHg pre- and postoperation, respectively, showing a statistically significant difference (t = 2.222, p = 0.041). In addition, the mean visual acuity was 4.15 ± 0.31 preoperation. After operation, the visual acuity increased to 4.63 ± 0.19 significantly (t = -9.908, p < 0.001). The IOP of all patients was within the normal range. During the long-term follow-up, no obvious abnormality appeared in the IOP of all patients.

Table 3 Comparisons of IOP and visual acuity before and after the operation (\(\bar x \pm s\))

Changes of corneal endothelial cells before and after the operation

As illustrated in Table 4, the mean CD at one day after the operation (643.23 ± 111.04 cells/mm2) and at one month after the operation (644.31 ± 106.24 cells/mm2) were lower than that before the operation (709.62 ± 119.19 cells/mm2), and the differences between preoperation and one month after operation were statistically significant (F = 21.234, p < 0.001). However, compared with preoperative CV (31.31 ± 4.11), no statistically significant difference was found in the CV values at one month postoperatively (32.62 ± 3.80; F = 2.130, p = 0.157). Moreover, the mean CCT at one day after the operation (587.07 ± 35.00 μm) and one month after the operation (562.71 ± 27.82 μm) were larger than that before the operation (534.79 ± 24.69 μm), with statistically significant differences (F = 27.953, p < 0.001). At one day after the operation, corneal stromal edema and wrinkling of a posterior elastic layer occurred in 5 eyes, all of which were from patients with grade IV nuclear cataracts. These phenomena gradually subsided 3–10 days after the operation. The cornea was transparent in the remaining patients, and there was no wrinkle in the posterior elastic layer. The CCT was larger than 600 μm in 2 eyes during the follow-up, but it was not detectable in 3 of the eyes. However, the cornea remained transparent for a long time during the follow-up, and there was no case of bullous keratopathy.

Table 4 Comparisons of CD, CV, and CCT before and after the operation (\(\bar x \pm s\))

Correlations of each factor with corneal endothelial cell loss rate and CCT after the operation

The loss rate of corneal endothelial cells after the operation had no significant correlations with CV before the operation. Besides, the CCT after the operation was not significantly related to CV before the operation. According to the correlation analysis, the CV before the operation was positively related to the CV at one day after the operation, with a correlation coefficient of 0.893, and it was positively correlated with CV at one month after the operation, with a correlation coefficient of 0.929.

Discussion

The structural integrity and functional soundness of the corneal endothelial cell layer are crucial for maintaining the normal physiological function of the cornea. Decreased endothelial CD and endothelial pump dysfunction result in corneal endothelial edema, which seriously damages visual acuity [4]. Cataracts patients with the symptoms mentioned above are intractable. And they will be at the risk of blindness if not treated. In this study, patients with low corneal endothelial CD received cataract extraction combined with IOL implantation, and all of them gained functional visual acuity after the operation. Although their postoperative visual acuity might not return to the normal level, it could be remarkably improved and remain stable for a long time, which substantially improved the patients’ quality of life [5].

Both ultrasound energy and mechanical shear force can reduce endothelial cells in cataract extraction. According to the reports of previous studies, corneal endothelial cells are decreased by 4–25% on average after phacoemulsification combined with IOL implantation [6, 7]. Patients with low endothelial cells have a very high sensitivity to injuries [8]. A study by Ken Hayahihi et al. has shown that the difference in the loss rate of corneal endothelial cells is not statistically significant between patients receiving cataracts extraction and normal patients. The corneal edema rate is high after the operation, but it recovers 1 month after the operation [9]. A study by Yamazoe et al. [10] has revealed no significant difference in endothelial cell loss after phacoemulsification in patients with low corneal endothelial CD complicated by grade IV or below nuclear cataracts. However, extracapsular cataract extraction may be better for patients with grade V nuclear cataracts. In the present study, the nuclear cataracts of all the patients were in grades III–IV, so all of them underwent phacoemulsification.

As indicated by the relevant literature and clinical practice, endothelial cell injury after phacoemulsification mainly results from mechanical and thermal injuries [11]. The mechanical injury is primarily caused by the insertions and removal of phacoemulsification needles and the rotation of lens nuclear fragments in the eye, whereas the thermal injury is mainly associated with phacoemulsification energy [2, 12, 13]. Hence, phacoemulsification was performed under low perfusion with low negative pressure in this study, which prevented the injury of corneal endothelium from excessive phacoemulsification energy and improved the anterior chamber stability, thus contributing to the IOP control and the occurrence of the shallow anterior chamber [14]. Besides, the hardness of the lens nucleus was all in grades III–IV, and the phacoemulsification was performed in a short time period under low energy [3]. The short-time and low-energy phacoemulsification parameters and skillful operations minimized the injury of corneal endothelial cells [15]. Among 17 eyes, only 5 had corneal edema after the operation, and the edema obviously subsided one month after the operation. Although only 2 eyes had postoperative CCT exceeding 600 μm, corneal decompensation did not occur. The following advantages characterize the phacoemulsification technology with small parameters: (1) The anterior chamber is slightly disturbed, so the incidence rates of surge phenomenon, shallow anterior chamber, and vitreous prolapse during operation can be reduced. (2) The suction of viscoelastic agents is slowed down to effectively protect the corneal endothelium. (3) The lens nucleus is slowly smashed to increase the operation’s safety. (4) Low perfusion pressure can limit the increase of IOP during phacoemulsification and avoid the injury of the corneal endothelium caused by high IOP during operation.

Effective surgical techniques were adopted to protect endothelial cells against injury to the largest extent during operation [16]. The loss rate of endothelial cells was 8.99% in patients with a small corneal endothelial cell count, which could be attributed to the low perfusion pattern with low negative pressure adopted during operation. This result is similar to the study results of Doors and Chen; that is, the higher the total ultrasound energy and the longer the ultrasound time, the more serious the corneal endothelial cell injury [17, 18].

Previous literature has reported that it is of great significance to evaluate corneal endothelial cells’ area, number, and morphology to determine the corneal endothelium’s health condition [19]. The injured corneal endothelial cells will experience death and there is no chance of recovery. The missing endothelial cells are repaired by the enlargement and migration of their surrounding corneal endothelial cells, so the endothelial cell area will become larger, and the normal hexagonal appearance will disappear after injury [20, 21]. CV is an index for endothelial deformation, whose sensitivity is higher than CD in reflecting endothelial dysfunction. The larger the CV, the more notable the inconsistency of the cell area. With poor endothelial function, patients with low corneal endothelial CD are more sensitive to injury, and their cells are larger in areas with higher heteromorphism [22]. In this study, CV had no statistically significant difference in patients with low corneal endothelial CD before and after the operation, indicating the effectiveness and significance of protecting the corneal endothelium during operation.

CCT is another index reflecting the functional state of the corneal endothelium. The corneal endothelium damaged during cataracts extraction will cause corneal edema and increase the corneal thickness [23, 24]. In the present study, the postoperative mean CCT was significantly increased compared with preoperation. Among 17 eyes, 2 eyes had CCT > 600 μm after the operation, but corneal endothelial dysfunction was found in none of them during the follow-up. The CD was not detectable before and after operation in 4 patients, with three eyes had undetectable CCT. However, phacoemulsification was performed since they had transparent corneas and grade III nuclear cataracts, and their corneas remained transparent after brief edema in the postoperative follow-up.

In this study, the reason corneal endothelial cells have low density but can tolerate phacoemulsification and IOL implantation is that, apart from a series of procedures taken to protect the endothelium during the operation, the apoptosis of corneal endothelial cells caused by chronic inflammation is a long process, in which the surrounding endothelial cells repeatedly deform, migrate, and fuse [25]. This process enhances the pump function and increases the expansion potential of endothelial cells. That is, the maximum healing reserve is gradually increased [26]. However, studies reveal that temporarily transparent corneas in patients may gradually develop corneal edema or even corneal decompensation 5 years after the operation. The limitations of this study include the small sample size and short follow-up time.

Conclusions

This study demonstrates that phacoemulsification with low perfusion pattern and low negative pressure is safe and effective for patients suffering from cataract and corneal endothelial cell dysfunction. Further studies that containing more samples and long follow-up time are needed to confirm the findings.

Data Availability

The data analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

IOL:

Intraocular lens

CD:

Cell density

CV:

Cell variation

CCT:

Central corneal thickness

IOP:

Intraocular pressure

RM ANOVA:

Repeated measures analysis of variance

References

  1. Greene JB, Mian SI. Cataract surgery in patients with corneal disease. Curr Opin Ophthalmol. 2013;24(1):9–14.

    Article  PubMed  Google Scholar 

  2. Bourne RR, Minassian DC, Dart JK, Rosen P, Kaushal S, Wingate N. Effect of cataract surgery on the corneal endothelium: modern phacoemulsification compared with extracapsular cataract surgery. Ophthalmology. 2004;111(4):679–85.

    Article  PubMed  Google Scholar 

  3. Verma V, Singh P, Patel S, Sharma B. Commentary: endotheial cell damage during cataract surgery: choosing the best technique. Indian J Ophthalmol. 2022;70(11):3910–1.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Hsu KM, Chang SH, Brothers W, Edelstein SL, Hsu HY, Harocopos GJ. Indications for Keratoplasty at 3 academic Centers from 2002 to 2012. Eye Contact Lens. 2016;42(6):374–9.

    Article  PubMed  Google Scholar 

  5. Tsao YT, Wu WC, Chen KJ, Yeh LK, Hwang YS, Hsueh YJ, Chen HC, Cheng CM. Analysis of aqueous humor total antioxidant capacity and its correlation with corneal endothelial health. Bioeng Transl Med. 2021;6(2):e10199.

    Article  CAS  PubMed  Google Scholar 

  6. Thakur SK, Dan A, Singh M, Banerjee A, Ghosh A, Bhaduri G. Endothelial cell loss after small incision cataract surgery. Nepal J Ophthalmol. 2011;3(2):177–80.

    Article  PubMed  Google Scholar 

  7. Feizi S. Corneal endothelial cell dysfunction: etiologies and management. Ther Adv Ophthalmol. 2018;10:2515841418815802.

    PubMed  PubMed Central  Google Scholar 

  8. Traish AS, Colby KA. Approaching cataract surgery in patients with fuchs’ endothelial dystrophy. Int Ophthalmol Clin. 2010;50(1):1–11.

    Article  PubMed  Google Scholar 

  9. Hayashi K, Yoshida M, Manabe S, Hirata A. Cataract surgery in eyes with low corneal endothelial cell density. J Cataract Refract Surg. 2011;37(8):1419–25.

    Article  PubMed  Google Scholar 

  10. Yamazoe K, Yamaguchi T, Hotta K, Satake Y, Konomi K, Den S, Shimazaki J. Outcomes of cataract surgery in eyes with a low corneal endothelial cell density. J Cataract Refract Surg. 2011;37(12):2130–6.

    Article  PubMed  Google Scholar 

  11. Nayak BK, Shukla RO. Effect on corneal endothelial cell loss during phacoemulsification: fortified balanced salt solution versus Ringer lactate. J Cataract Refract Surg. 2012;38(9):1552–8.

    Article  PubMed  Google Scholar 

  12. Ho JW, Afshari NA. Advances in cataract surgery: preserving the corneal endothelium. Curr Opin Ophthalmol. 2015;26(1):22–7.

    Article  PubMed  Google Scholar 

  13. Gogate P, Ambardekar P, Kulkarni S, Deshpande R, Joshi S, Deshpande M. Comparison of endothelial cell loss after cataract surgery: phacoemulsification versus manual small-incision cataract surgery: six-week results of a randomized control trial. J Cataract Refract Surg. 2010;36(2):247–53.

    Article  PubMed  Google Scholar 

  14. Hwang HB, Lyu B, Yim HB, Lee NY. Endothelial cell loss after Phacoemulsification according to different Anterior Chamber Depths. J Ophthalmol. 2015;2015:210716.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Ho YJ, Sun CC, Chen HC. Cataract surgery in patients with corneal opacities. BMC Ophthalmol. 2018;18(1):106.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Díez-Ajenjo MA, Luque-Cobija MJ, Peris-Martínez C, Ortí-Navarro S, García-Domene MC. Refractive changes and visual quality in patients with corneal edema after cataract surgery. BMC Ophthalmol. 2022;22(1):242.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Chen HC, Huang CW, Yeh LK, Hsiao FC, Hsueh YJ, Meir YJ, Chen KJ, Cheng CM, Wu WC. Accelerated corneal endothelial cell loss after Phacoemulsification in patients with mildly low endothelial cell density. J Clin Med 2021, 10(11).

  18. Doors M, Berendschot TT, Touwslager W, Webers CA, Nuijts RM. Phacopower modulation and the risk for postoperative corneal decompensation: a randomized clinical trial. JAMA Ophthalmol. 2013;131(11):1443–50.

    Article  PubMed  Google Scholar 

  19. Ianchulev T, Lane S, Masis M, Lass JH, Benetz BA, Menegay HJ, Price FW, Lin S. Corneal endothelial cell density and morphology after phacoemulsification in patients with Primary Open-Angle Glaucoma and cataracts: 2-Year results of a Randomized Multicenter Trial. Cornea. 2019;38(3):325–31.

    Article  PubMed  Google Scholar 

  20. Lass JH, Benetz BA, He J, Hamilton C, Von Tress M, Dickerson J, Lane S. Corneal endothelial cell loss and morphometric changes 5 years after phacoemulsification with or without CyPass Micro-Stent. Am J Ophthalmol. 2019;208:211–8.

    Article  PubMed  Google Scholar 

  21. Mahdy MA, Eid MZ, Mohammed MA, Hafez A, Bhatia J. Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery. Clin Ophthalmol. 2012;6:503–10.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Choi JY, Han YK. Long-term (≥ 10 years) results of corneal endothelial cell loss after cataract surgery. Can J Ophthalmol. 2019;54(4):438–44.

    Article  PubMed  Google Scholar 

  23. Lee KM, Kwon HG, Joo CK. Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system. J Cataract Refract Surg. 2009;35(5):874–80.

    Article  PubMed  Google Scholar 

  24. Joyce NC. Proliferative capacity of corneal endothelial cells. Exp Eye Res. 2012;95(1):16–23.

    Article  CAS  PubMed  Google Scholar 

  25. Galgauskas S, Norvydaitė D, Krasauskaitė D, Stech S, Ašoklis RS. Age-related changes in corneal thickness and endothelial characteristics. Clin Interv Aging. 2013;8:1445–50.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Kim DH, Wee WR, Hyon JY. The pattern of early corneal endothelial cell recovery following cataract surgery: cellular migration or enlargement? Graefes Arch Clin Exp Ophthalmol. 2015;253(12):2211–6.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We are thankful for patients who participated in this study.

Funding

This work was supported by the Science and Technology Innovation joint Fund Project of Fujian Provincial Department of Science and Technology(No. 2021Y9013) and the Qihang Funds of Fujian Medical University (No. 2021QH1079). The funding organizations had no role in the design and conduct of this study.

Author information

Authors and Affiliations

Authors

Contributions

XW, YZ and YL contributed to the conception and design of the study; YL, YY, and QY collected the clinical data; YL and BZ performed the statistical analysis and wrote the manuscript; XW reviewed the manuscript. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Yihua Zhu or Xiaohui Wang.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics approval and consent to participate

This study was approved by the Ethics Committee of the First Affiliated Hospital of Fujian Medical University and was conducted in accordance with the principle of the Declaration of Helsinki. Written informed consent was obtained from the patients.

Consent for publication

Not applicable.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lin, Y., Zhou, B., Yao, Y. et al. Clinical observation of phacoemulsification under the low perfusion pattern and low negative pressure in patients with low corneal endothelial cell density. BMC Ophthalmol 23, 340 (2023). https://doi.org/10.1186/s12886-023-03095-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-023-03095-w

Keywords