Skip to main content

Eiology and prognosis of canalicular laceration repair using canalicular anastomosis combined with bicanalicular stent intubation

Abstract

Background

To evaluate the etiology of lacrimal canalicular laceration and explore the possible risk factors influencing prognosis.

Methods

The data of 142 patients (142 eyes) with lacrimal canalicular lacerations who were surgically treated using canalicular anastomosis combined with bicanalicular stent intubation between March 2017 and March 2018 were reviewed. The analyzed data contained demographic information, types of trauma, injury locations, associated additional ocular injuries, and surgical outcomes at follow-up. The main outcome measures were anatomic success rate, functional success rate, and complications of surgery.

Results

The mean patient age was 42.07 years (ranging from 1 to 75 years). Among the 142 patients, 112 (78.87%) were males. Upper and lower canalicular lacerations were found in 14 (9.86%) and 112 (78.87%) patients, respectively. Meanwhile, both upper and lower canalicular lacerations were found in 16 (11.27%) patients. Electric bike accidents comprised the leading cause of injury, accounting for 76 (53.52%) cases. There were 100 (70.42%) patients who had lid lacerations without tarsal plate fracture and 42 (29.58%) patients who had lid lacerations with tarsal plate fractures. The anatomic success rate was 98.59% and the functional success rate was 83.8%. The functional reconstruction failure rates were higher in patients with indirect injuries, lid lacerations with tarsal plate fractures, and those with punctum splitting (P < 0.05). Surgical complications were detected in the form of lacrimal punctum ectropion in 3 (2.11%) patients, punctum splitting in 2 (1.41%) patients, and stent extrusion and loss in 2 (1.41%) patients.

Conclusions

Electric bike accidents have become the leading cause of injury instead of motor vehicle accidents because of the changes in the lifestyles of people. Indirect injuries, lid lacerations with tarsal plate fractures, and those with punctum splitting were significantly more likely to lead to poor prognosis, as confirmed by the lower functional success rate of surgery.

Peer Review reports

Background

Canalicular laceration, which is commonly regarded as an ocular emergency, is caused by trauma on the eyelids and in periorbital areas. It frequently involves the lower canaliculus and its incidence has been reported in all age groups [1]. Canalicular lacerations are present in approximately 16% of all eyelid lacerations due to ocular trauma [2]. It has been reported that 72% of lower canaliculus lacerations are monocanalicular, whereas bicanalicular lacerations account for 6 to 24% of all canalicular injuries [3]. Based on the mechanisms of damage, Wulc et al. divided canalicular lacerations into direct trauma, such as knife and dog bite injuries, and indirect trauma, such as blunt trauma [4]. It has been reported that the condition of patients with canalicular lacerations due to indirect or diffused injuries can be attributed to factors other than the presence of penetrating injuries [4].

The canaliculus can undergo stenosis, causing lacrimal drainage dysfunction with epiphora, if not appropriately managed [5]. Canalicular anastomosis, combined with bicanalicular or monocanalicular stent intubation, is used for primary canalicular laceration repairs [5]. A variety of materials have been used to stent torn canaliculus clinically [6, 7], such as medical-grade silicone stents (Freda® silicone tube, mini-Monoka®, Masterka®) [8, 9]. The mini-Monoka® is a monocanalicular stent composed of a silicon rod with a bulb and a collar at the proximal end, making it self-retaining [8]. The mini-Monoka® insertion is suitable for conditions such as canalicular laceration involving the external two-thirds of the canaliculus without damaging the canthal ligament. Silicone intubation is most commonly used in surgery because of its advantageous attributes, namely, inert nature, flexibility, and easy availability [6, 7]. Several factors impact the effectiveness of laceration repair, including the extent and location of canalicular lacerations, the intubation materials, the duration of intubation, and the surgical technique [10,11,12]. The present study was conducted to review the cases of 142 patients with primary canalicular lacerations in the Department of Ophthalmology of Shanghai Ninth People’s Hospital, China. We described the epidemiology and evaluated the etiology and prognosis of primary canalicular laceration repair using canalicular anastomosis combined with bicanalicular stent intubation.

Methods

Patients

We retrospectively reviewed the medical records of 142 patients (142 eyes) who had primary canalicular lacerations and required surgical repair within 48 h at the Department of Ophthalmology, Shanghai Ninth People’s Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China between March 2017 and March 2018. Most of the patients were initially referred to the emergency room, while the others were recruited from clinics. The retrospective study was performed with the approval of the Ethics Committee of Shanghai Ninth People’s Hospital, Shanghai JiaoTong University School of Medicine, China. The informed consent and the commitment to follow-up were signed by all subjects in our study, including the parents or guardians of the study participants who were minors at the time of study. The patients comprised 112 males and 30 females who were 1 to 75 years old (42.07 years on average). Among the 142 patients, 134 received indirect injuries and 8 received direct injuries. The patient demographics, affected canaliculus, number of canaliculus injured, nature of injury, and associated injuries were obtained through patient records. The data on the complications and surgical success rate were also collected for this study, as the post-surgery follow-up visits were recorded at 1.0 week and at 1.0, 2.0, 3.0, and 6.0 months after surgery. The exclusion criteria included lack of adequate follow up (< 3 months), pre-injury epiphora and pyorrhea, additional lacerations involving the lacrimal sac and/or nasolacrimal duct or congenital and/or acquired lacrimal stenosis and/or obstruction.

Lacrimal system evaluation

We evaluated the lacrimal system before surgery and estimated whether the lacrimal system was involved when the eyelid laceration was situated very close to the medial canthus. Further examination of the lacrimal system was done by irrigation of the lacrimal canaliculi with a 2.0 ml syringe of 0.9% saline solution under topical anesthesia. If the liquid flowed from the wound, a lacrimal probe was used to confirm the position of the distal lacerated end of the lacrimal canaliculus and the distance from the lacrimal punctum and the distal lacerated end was measured.

Surgical procedure

Routine sterilization was conducted and infratrochlear and infraorbital nerve block anesthesia was administered with 2.0 ml of 2% lidocaine and 2.0 ml of 0.75% bupivacaine for adults. General anesthesia was also administered for the pediatric patients. The proximal lacerated end was located with the aid of a surgical microscope (ZEISS, Germany). Then, a punctum dilator was used to enlarge the lacrimal punctum. Bicanalicular silicone tube intubation was done using a 1.0 mm-diameter silicone tube with a probe at both heads (Shandong Freda Biotechnology Co., Ltd., China), as shown in Fig. 1. One head was inserted into the ruptured canaliculus and nasal cavity, while the other end was placed into the upper or lower canaliculus and pulled out from the nasal cavity. The proximal and distal lacerated ends were subsequently anastomosed with 6–0 absorbable suture of polydioxanone (Johnson&Johnson, USA) around the silicone tube. The meticulous re-approximation of the severed canaliculus was performed under an ophthalmic surgical microscope. The two corresponding ends of the silicone tube were tied securely at a proper length. If any globe injury occurred, globe wound repair had to be performed before other management treatments. Repairs of additional eyelid injuries were conducted after the lacrimal intubation. The preoperative and postoperative images of a typical case are provided in Fig. 2. All repairs were performed by the same experienced surgeon.

Fig. 1
figure 1

The silicone stent (Shandong Freda Biotechnology Co., Ltd., China)

Fig. 2
figure 2

A female patient with lower lacrimal canalicular laceration and full-thickness eyelid laceration of her left eye. a Preoperative view of the patient; b Postoperative view of the patient by surgery of silicone intubation. Intubation of a bicanalicular silicone stent was seen after surgery

Postoperative management

Antibiotics were simultaneously administrated locally and intravenously to prevent infection. Post-surgery follow-up visits were recorded at 1.0 week and at 1.0, 2.0, 3.0, and 6.0 months. The silicone tube was shifted and checked monthly and extubation was performed 3 to 6 months after surgery, followed by lacrimal irrigation. The surgery outcome was defined by lacrimal irrigation and the presence of symptomatic epiphora indoors.

Statistical analysis

Data were presented as mean + SD or n patients. The SPSS 22.0 software was used for statistical analysis. The clinical prognoses and surgical outcomes of the canalicular lacerations were compared using Chi Square test. Kaplan–Meier analysis and Cox proportional hazards regression analysis were used to determine the risk factors influencing the prognosis of canalicular laceration. All P values were considered statistically significant when the values were < 0.05.

Results

In our study, 112 (78.87%) of the patients were males and 30 (21.13%) were females. The average age was 42.07 years (ranging from 1 to 79 years). A total of 126 (88.7%) patients had one canaliculus involved, 16 (11.3%) had 2 canaliculi involved, and no patient had 3 or 4 canaliculi involved. Upper and lower canalicular lacerations were found in 14 (9.86%) and 112 patients (78.87%), respectively, while both canalicular lacerations were found in 16 patients (11.27%). The mean time interval between injury and surgery was 14.42 + 0.36 h (from 3 to 48 h). The mean time of canalicular stent removal was 4.5+ 0.54 months and the mean follow-up period was 6.94 + 0.51 months (Table 1).

Table 1 Clinical characteristics of patients undergoing Canalicular laceration repair

The types of trauma that caused the canalicular lacerations are shown in Table 1. Among the patients, indirect canalicular injuries were detected in 134 (94.4%), which were remarkably more frequent than direct injuries, which were detected in only 8 (5.6%) patients. Electric bike accidents comprised the leading cause of injury, accounting for 76 (53.52%) patients. The other mechanisms of injury were blunt injuries for 32 (22.54%) patients, car accidents for 10 (7.04%) patients, fights for 4 (2.82%) patients, falls for 12 (8.45%) patients, sharp objects for 6 (4.22%) patients, and dog bites for 2 (1.41%) patients, as shown in Table 1.

Other additional injuries associated with trauma that afflicted the patients are also presented in Table 1. There were 100 (70.42%) patients who had lid lacerations without a tarsal plate fracture and 42 (29.58%) patients with tarsal plate fractures. Canalicular laceration combined with globe rupture occurred in 6 (4.23%) patients in terms of additional injuries. Some patients may have experienced two or more additional injuries at the same time. Other injuries associated with the trauma are as follows: 14 (9.86%) extraocular muscle injuries, 10 (7.04%) head trauma, 7 (4.93%) ptosis, 2 (1.41%) optic neuropathies, and 2 (1.41%) vitreous and/or retinal detachments (Table 1).

All of the canalicular lacerations were repaired during this study. The mean time of canalicular stent removal was 4.5 + 0.54 months. During the follow-up visits, there were two patients with stent extrusion and loss because of a loose knot and because the patients had pulled the suture out. No patient suffered from infection of the lacrimal canaliculus during the visits.

The surgery outcomes of the canalicular lacerations are presented in Table 2. After stent removal, the patients underwent irrigation of the lacrimal canaliculus. They were asked about epiphora during the follow-up. All 142 patients exhibited anatomic success, notwithstanding the two patients with stent extrusion and loss. Among the patients who demonstrated anatomic success, 119 (83.8%) were cases of functional success, claiming no epiphora. As shown in Table 2, among the upper, lower, and both canalicular laceration repair surgeries, there was no significant difference between the anatomic success and functional success rates (P > 0.05; P > 0.05). The data also showed no significant difference in the anatomic success rate between indirect and direct injuries.

Table 2 Outcomes of canaliculus anastomosis and bicanalicular stent intubation

As shown in Table 2, the functional success rate was significantly lower in indirect injuries than direct injuries (P < 0.01). Between the canalicular laceration with and without tarsal plate fracture, there was no significant difference in anatomic success rate. However, surgery had a higher functional success rate in the canalicular lacerations without tarsal plate fracture than in those with tarsal plate fractures (P < 0.01). Between the canalicular laceration with and without punctum splitting, no significant difference was shown in the anatomic success rate. However, surgery had a higher functional success rate in the canalicular lacerations without punctum splitting than in those with punctum splitting (P < 0.01). Regarding the surgery complications, we only found 3 (2.11%) patients with lacrimal punctum ectropion (Fig. 3) and 2 (1.41%) patients with punctum splitting (Fig. 4). No patient had a false path.

Fig. 3
figure 3

The figure of complication with lacrimal punctum ectropion and splitting

Fig. 4
figure 4

The figure of complication with lacrimal punctum splitting

The results of the Kaplan–Meier analysis for treatment success rate are shown in Table 3. The Cox proportional hazards regression analysis of prognostic factors in canaliculus laceration repair surgery are also presented. Notably, canalicular lacerations with indirect injury, tarsal plate fracture, and punctum splitting were significantly more likely to have poor prognosis (P = 0.017, 0.036, and 0.045).

Table 3 Cox proportional hazards regression analysia of risk factors for the canalicular lacerations

Discussion

Canalicular laceration commonly accompanies facial trauma and requires early intervention (within 48 h) in the ophthalmology department to restore anatomy and function [4]. Canalicular lacerations are pervasive among males, accounting for about 78.87% in our study, similar to the results of Naik et al., who reported 86% male cases [8]. In this study, patients with lower canalicular laceration involvement were predominant (78.87%). Liang et al. reported that 82.9% had lower canalicular lacerations, 11.4% had upper canalicular lacerations, and 5.7% had bicanalicular lacerations in their studies [13]. Our data corresponded with the findings of the above studies. Our mean time between injury and repair is 14.42+ 0.36 h (from 3 to 48 h). Some authors posit that early treatment (9–32 h) is the key to success in canalicular repair [8, 14]. Tint et al. showed poor outcomes in 6 out of 40 patients with delayed repair (2–3 days) [14]. By contrast, Chatterjee et al. reported five patients who presented between 2 to 4 days since their injuries but still had successful outcomes after surgery [15].

Although the epidemiology of canalicular laceration had been published in some reports, the types of traumas that cause these injuries have changed due to the altered lifestyles of people. In our study, electric bike accidents comprised the leading cause of injury, accounting for 76 (53.52%) patients, instead of motor vehicle accidents (35.81%), as was the case in the past [16]. Electric bikes have replaced motor vehicles due to their advantageous attributes, such as being inexpensive and environment friendly. With the increase in the number of electric bikes, the related rate of accidents is also increasing. We also found that patients with indirect canalicular injuries were remarkably more predominant than those with direct injuries, similar to the results derived by Wulc et al. [4].

Our study showed that the rate of patients who had lid lacerations with tarsal plate fractures was 29.58%. As there are no previous data on the incidence of tarsal plate fracture during injury, we concluded that lid lacerations without tarsal plate fracture are more frequent than those with tarsal plate fractures. In our study, globe rupture occurred in 6 (4.23%) patients. Herzum et al. reported a 20 to 44% incidence rate for globe injury in association with eyelid injuries [2]. These results are quite different from our own. Lee et al. later reported that traumatic hyphema and subconjunctival hemorrhage represented the most frequent associated ocular injuries instead of globe injury [17].

It is believed that the key to a successful surgical repair of canalicular laceration is to find the proximal lacerated end quickly and precisely [18]. Several methods and techniques to identify the proximal lacerated end of the canaliculus, such as pigtail probe [19], upper canalicular probing, and bubble or colored opaque solution injection, have been presented in previous studies [17, 18, 20, 21]. Silicone intubation is the strategy that is most commonly used in surgery because of its capability of restoring a normal anatomical pathway to avoid a false path [5]. With double-passage canalicular intubation, circular stents using silicone tubes provide good stabilization, preserve the natural location of the medial canthus, and maintain the physiological anatomical reposition of the superior and inferior punctum, thereby preventing ectropion and laceration of the lower eyelid and inferior punctum. It also offers excellent tear drainage [5,6,7]. However, the disadvantages of double-passage canalicular intubation include symptoms of irritation and additional secretion [22]. All canalicular lacerations in our cases were repaired through double-passage canalicular intubation with successful anastomosis.

Among these patients, 140 (98.59%) had anatomic success and 119 (83.8%) had functional success. Kersten et al. described an alternative surgical approach for the repair of canalicular laceration using silicone tube intubation with a success rate of 96% based on lack of symptomatic epiphora [20]. Liang et al. reported that 91.18% of their patients experienced complete success with total disappearance of epiphora and 8.82% eyes achieved partial success after tube removal [13]. The results we obtained are similar to the literature reported above. Our results showed that certain factors, namely, indirect injuries, lid laceration with tarsal plate fracture, and those with lacrimal punctum splitting, led to lower functional success rate of surgery and were the risk factors for canalicular laceration repair surgery. The reason may be the severe scarring surrounding the canaliculus due to the tarsal plate fracture and lacrimal punctum splitting.

Conclusions

The causes of canalicular lacerations have changed because of the altered lifestyles of people. Our studies showed that certain factors, namely, indirect injuries, lid lacerations with tarsal plate fractures, and those with punctum splitting, led to lower functional success rate of surgery and were the risk factors for functional reconstruction after repair surgery. A drawback of this study is its retrospective, noncomparative nature. A large-scale study of a comparative nature is needed in the future. The results of the present study will provide some suggestions for the prognosis of surgical treatment for canalicular laceration.

Availability of data and materials

The datasets of the current study are available upon request from the co-correspondence author Jiali Ji and CaiWen Xiao.

References

  1. Bi Y, Sui G, Zhou Q, et al. Two-step retrograde closed stenting: a novel method for treating canalicular lacerations in Chinese patients. Eye. 2013;27:1275–80.

    Article  CAS  Google Scholar 

  2. Herzum H, Holle P, Hintschich C. Eyelid injuries: epidemiological aspects. Ophthalmologe. 2001;98:1079–82.

    Article  CAS  Google Scholar 

  3. Ejstrup R, Wiencke AK, Toft PB. Outcome after repair of concurrent upper and lower canalicular lacerations. Orbit. 2014;33:169–72.

    Article  Google Scholar 

  4. Wulc AE, Arterberry JF. The pathogenesis of canalicular laceration. Ophthalmology. 1991;98:1243–9.

    Article  CAS  Google Scholar 

  5. Spinelli HM, Shapiro MD, Wei LL, et al. The role of lacrimal intubation in the management of facial trauma and tumor resection. Plast Reconstr Surg. 2005;115:1871–6.

    Article  CAS  Google Scholar 

  6. Walter WL. The use of the pigtail probe for silicone intubation of the injured canaliculus. Ophthalmic Surg. 1982;13:488–92.

    CAS  PubMed  Google Scholar 

  7. Cho SH, Hyun DW, Kang HJ, et al. A simple new method for identifying the proximal cut end in lower canalicular laceration. Korean J Ophthalmol. 2008;22:73–6.

    Article  Google Scholar 

  8. Naik MN, Kelapure A, Rath S, Honavar SG. Management of canalicular lacera- tions: epidemiological aspects and experience with mini-Monoka monocanalicular stent. Am J Ophthalmol. 2008;145:375–80.

    Article  Google Scholar 

  9. Tavakoli M, Karimi S, Behdad B, et al. Traumatic canalicular laceration repair with a new monocanalicular silicone tube. Ophthalmic Plast Reconstr Surg. 2017;33:27–30.

    Article  Google Scholar 

  10. Chu YC, Wu SY, Tsai YJ, et al. Early versus late canalicular laceration repair outcomes. Am J Ophthalmol. 2017;182:155–9.

    Article  Google Scholar 

  11. Singh S, Ganguly A, Hardas A, et al. Canalicular laceration: factors predicting outcome at a tertiary eye care centre. Orbit. 2017;36(1):13–8.

    Article  Google Scholar 

  12. Singh M, Gautam N, Ahir N, Kaur M. Is the distance from punctum a factor in the anatomical and functional success of canalicular laceration repairs? Indian J Ophthalmol. 2017;65(11):1114–9.

    Article  Google Scholar 

  13. Liang X, Lin Y, Wang Z, et al. A modified bicanalicular intubation procedure to repair canalicular lacerations using silicone tubes. Eye (Lond). 2012;26:1542–7.

    Article  CAS  Google Scholar 

  14. Tint NL, Alexander P, Cook AE, Leatherbarrow B. Eyelid avulsion repair with bi-canalicular silicone stenting without medial canthal tendon reconstruction. Br J Ophthalmol. 2011;95:1389–92.

    Article  Google Scholar 

  15. Chatterjee S, Rath S, Roy A, Shrestha E. 20G silicone rod as monocanalicular stent in repair of canalicular lacerations: experience from a tertiary eye care centre. Indian J Ophthalmol. 2013;61(10):585–6.

    Article  Google Scholar 

  16. Bai F, Tao H, Zhang Y, et al. Old canalicular laceration repair: a retrospective study of the curative effects and prognostic factors. Int J Ophthalmol. 2017;10:902–7.

    PubMed  PubMed Central  Google Scholar 

  17. Lee H, Chi M, Park M, Baek S. Effectiveness of canalicular laceration repair using monocanalicular intubation with Monoka tubes. Acta Ophthalmol. 2009;87:793–6.

    Article  Google Scholar 

  18. Liu B, Li Y, Long C, et al. Novel air-injection technique to locate the medial cut end of lacerated canaliculus. Br J Ophthalmol. 2013;97:1508–9.

    Article  Google Scholar 

  19. Loff HJ, Wobig JL, Dailey RA. The bubble test: an atraumatic method for canalicular laceration repair. Ophthal Plast Reconstr Surg. 1996;12:61–4.

    Article  CAS  Google Scholar 

  20. Wang L, Chen D, Wang Z. New technique for lacrimal system intubation. Am J Ophthalmol. 2006;142:252–8.

    Article  Google Scholar 

  21. Kersten RC, Kulwin DR. “One-stitch” canalicular repair. A simplified approach for repair of canalicular laceration. Ophthalmology. 1996;103:785–9.

    Article  CAS  Google Scholar 

  22. Benger RS, Nemet AY. Peripunctal “anchor” suture for securing the silicone bicanalicular stent in the repair of canalicular laceration. Ophthal Plast Reconstr Surg. 2008;24:51–3.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was supported by The National Natural Science Foundation of China (Grant No.81300779; Zhenzhen Zhang; The Natural Science Foundation of Liaoning Province of China (Grant No.20180550524; Xiuhong Qin); The Foundation of Liaoning Educational Committee (Grant No. LQ2017016; Xiuhong Qin) in collection, analysis, and interpretation of data, and in writing the manuscript.

Author information

Authors and Affiliations

Authors

Contributions

Conceived and designed the study: ZZZ, XCW and WHW; Acquisition of data: GT and QXH; Analysis and interpretation of data: JJL; Drafting the manuscript: LY and XL; All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Jiali Ji, Caiwen Xiao or Zhenzhen Zhang.

Ethics declarations

Ethics approval and consent to participate

This study was performed in accordance with the declaration of Helsinki and was approved by the Ethics Committee of the Shanghai Ninth People’s Hospital, Shanghai JiaoTong University school of Medicine, Shanghai, China. Written informed consent was obtained from all subjects after the aims and nature of the study were explained to the participants. The parents or guardians of the study participants who were minors at the time of study gave written consent for their particular children to be involved in the study. The administrative permissions were granted to access the medical files analysed in the study.

Consent for publication

Not Applicable.

Competing interests

The authors declare no conflict of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guo, T., Qin, X., Wang, H. et al. Eiology and prognosis of canalicular laceration repair using canalicular anastomosis combined with bicanalicular stent intubation. BMC Ophthalmol 20, 246 (2020). https://doi.org/10.1186/s12886-020-01506-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-020-01506-w

Keywords